EMD-5027
Kinesin13-Microtubule Ring Complex
EMD-5027
Helical reconstruction28.0 Å
Deposition: 29/08/2008Map released: 05/05/2009
Last modified: 02/04/2014
Concentration: 0.6
mg/mL
Buffer
pH: 6.8
Details: 80 mM Pipes, pH 6.8, 2 mM MgCl2, 1 mM EGTA, 2 mM AMP-PNP, 0.02 mM taxol
Details: 80 mM Pipes, pH 6.8, 2 mM MgCl2, 1 mM EGTA, 2 mM AMP-PNP, 0.02 mM taxol
Grid
Details: Quantifoil grids
Microscope: FEI TECNAI 20
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: LAB6
Acceleration voltage: 120 kV
Nominal defocus: 1.5 µm - 2.5 µm
Nominal magnification: 50000.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry liquid nitrogen-cooled cryo specimen holder
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: LAB6
Acceleration voltage: 120 kV
Nominal defocus: 1.5 µm - 2.5 µm
Nominal magnification: 50000.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry liquid nitrogen-cooled cryo specimen holder
Image Recording
[1]
Detector category:
FILM
Detector model: KODAK SO-163 FILM
Scanner: OTHER
Sampling interval: 12.5 µm
Number of real images: 5
Average electron dose per image: 9 e/Å2
Bits per pixel: 16.0
Detector model: KODAK SO-163 FILM
Scanner: OTHER
Sampling interval: 12.5 µm
Number of real images: 5
Average electron dose per image: 9 e/Å2
Bits per pixel: 16.0
Microscope: FEI TECNAI F20
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal magnification: 50000.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry liquid nitrogen-cooled cryo specimen holder
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal magnification: 50000.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry liquid nitrogen-cooled cryo specimen holder
Image Recording
[1]
Detector category:
FILM
Detector model: KODAK SO-163 FILM
Scanner: OTHER
Sampling interval: 12.5 µm
Number of real images: 5
Average electron dose per image: 9 e/Å2
Bits per pixel: 16.0
Detector model: KODAK SO-163 FILM
Scanner: OTHER
Sampling interval: 12.5 µm
Number of real images: 5
Average electron dose per image: 9 e/Å2
Bits per pixel: 16.0
Final
reconstruction
Resolution: 28.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
Software
[1]
| Name | Version | Details |
|---|---|---|
| MRC, SUPRIM, Phoelix, Other | - | - |
CTF correction
Details: Each Particle
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Kinesin 13-Microtubule Ring Complex
Details: ::::EMDATABANK.org::::EMD-5027::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Kinesin 13-Microtubule Ring Complex
Details: ::::EMDATABANK.org::::EMD-5027::::
⬡ Geometry
| X | Y | Z | |
|---|---|---|---|
| Origin | 0 | 0 | 0 |
| Dimensions (px) | 101 | 101 | 41 |
| Dimensions (Å) | 606.0 | 606.0 | 246.0 |
| Voxel size (Å) | 6.0 | 6.0 | 6.0 |
Contour list
| Primary | Level | Source |
|---|---|---|
| True | 11.1 | AUTHOR |
