EMD-2896
Cryo-EM structure of helical ANTH and ENTH tubules on PI(4,5)P2-containing membranes
EMD-2896
Single-particle13.6 Å
Deposition: 10/02/2015Map released: 06/05/2015
Last modified: 27/05/2015
Buffer
pH: 7.5
Details: 20 mM HEPES, pH 7.5; 100 mM KCl
Details: 20 mM HEPES, pH 7.5; 100 mM KCl
Grid
Details: On C-flat holey carbon coated grids (Protochips)
Vitrification
Cryogen name: ETHANE
Chamber humidity: 80%
Instrument: HOMEMADE PLUNGER
Method: , applied on C-flat holey carbon coated grids (Protochips) and vitrified
Chamber humidity: 80%
Instrument: HOMEMADE PLUNGER
Method: , applied on C-flat holey carbon coated grids (Protochips) and vitrified
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 120 kV
Nominal CS: 2.7 mm
Nominal defocus: 0.5 µm - 5.0 µm
Nominal magnification: 59000.0
Calibrated magnification: 59000.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 120 kV
Nominal CS: 2.7 mm
Nominal defocus: 0.5 µm - 5.0 µm
Nominal magnification: 59000.0
Calibrated magnification: 59000.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Image Recording
[1]
Detector category:
CCD
Detector model: GATAN ULTRASCAN 4000 (4k x 4k)
Number of real images: 1419
Average electron dose per image: 10 e/Å2
Detector model: GATAN ULTRASCAN 4000 (4k x 4k)
Number of real images: 1419
Average electron dose per image: 10 e/Å2
Details: Processing done with SPRING
Final
reconstruction
Resolution: 13.6
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 457344
Details:
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 457344
Details:
⌯ Applied Symmetry
Software
[1]
| Name | Version | Details |
|---|---|---|
| SPRING | - | - |
CTF correction
Details: Each Particle
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Reconstruction of the 10.04 units per turn, 127.2 Angstrom pitch, helical assembly of ANTH-ENTH on PIP2 containing membrane
Details: ::::EMDATABANK.org::::EMD-2896::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Reconstruction of the 10.04 units per turn, 127.2 Angstrom pitch, helical assembly of ANTH-ENTH on PIP2 containing membrane
Details: ::::EMDATABANK.org::::EMD-2896::::
⬡ Geometry
| X | Y | Z | |
|---|---|---|---|
| Origin | -120 | -120 | -170 |
| Dimensions (px) | 240 | 240 | 340 |
| Dimensions (Å) | 427.19998 | 427.19998 | 605.2 |
| Voxel size (Å) | 1.78 | 1.78 | 1.7800001 |
Contour list
| Primary | Level | Source |
|---|---|---|
| True | 0.35 | AUTHOR |
