EMD-2431

Subtomogram averaging
40.0 Å
EMD-2431 Deposition: 26/07/2013
Map released: 18/09/2013
Last modified: 09/10/2013
Overview 3D View Sample Experiment Validation Additional data Links
Overview 3D View Sample Experiment Validation Additional data Links

EMD-2431

The structure of the COPII coat assembled on membranes

EMD-2431

Subtomogram averaging
40.0 Å
EMD-2431 Deposition: 26/07/2013
Map released: 18/09/2013
Last modified: 09/10/2013
Overview 3D View Sample Experiment Validation Additional data Links
Method: Subtomogram averaging
Aggregation State: Helical Array
Specimen preparation [1]
Concentration: 0.03 mg/mL
Buffer
pH: 6.8
Details: HEPES, 50 mM KOAc, 1.2 mM MgCl2
Staining
Type: NEGATIVE
Details: Plunge frozen
Grid
Details: C-flat grids
Vitrification
Cryogen name: ETHANE
Instrument: HOMEMADE PLUNGER
Microscopy [2]
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.7 mm
Nominal defocus: 2.0 µm - 3.2 µm
Nominal magnification: 19500.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Specialist optics
Energy filter
Image Recording [1]
Detector category: CCD
Detector model: GATAN MULTISCAN
Number of real images: 26
Average electron dose per image: 80 e/Å2
Bits per pixel: 16.0
Tilt Series [1]
Axis 1 Axis 2
Min. Max. Inc. Min. Max. Inc. Rotation
-60 ° 60 ° - - - - -
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.7 mm
Nominal defocus: 2.0 µm - 3.2 µm
Nominal magnification: 19500.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Specialist optics
Energy filter
Image Recording [1]
Detector category: CCD
Detector model: GATAN MULTISCAN
Number of real images: 26
Average electron dose per image: 80 e/Å2
Bits per pixel: 16.0
Tilt Series [1]
Axis 1 Axis 2
Min. Max. Inc. Min. Max. Inc. Rotation
-60 ° 60 ° - - - - -
Image processing [1]
Details: See materials and methods in relevant publication
Final reconstruction
Resolution: 40.0 Å ( BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
Details:
Applied Symmetry
Point group: C2
Software [1]
Name Version Details
TOM/AV3, Matlab - -
Final angle assignment
Details: 0 0 0 in zyz convention
CTF correction
Details: Each tilted image within tomogram
Map
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Sec13/31 complex (as part of complete coat assembled on membrane). Edge, right handed direction
Details: ::::EMDATABANK.org::::EMD-2431::::
Geometry
X Y Z
Origin 0 0 0
Dimensions (px) 72 72 72
Dimensions (Å) 309.6 309.6 309.6
Voxel size (Å) 4.3 4.3 4.3
Contour list
Primary Level Source
True 2.0 AUTHOR