EMD-2431
The structure of the COPII coat assembled on membranes
EMD-2431
Subtomogram averaging40.0 Å
Deposition: 26/07/2013Map released: 18/09/2013
Last modified: 09/10/2013
Concentration: 0.03
mg/mL
Buffer
pH: 6.8
Details: HEPES, 50 mM KOAc, 1.2 mM MgCl2
Details: HEPES, 50 mM KOAc, 1.2 mM MgCl2
Staining
Type:
NEGATIVE
Details: Plunge frozen
Details: Plunge frozen
Grid
Details: C-flat grids
Vitrification
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.7 mm
Nominal defocus: 2.0 µm - 3.2 µm
Nominal magnification: 19500.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.7 mm
Nominal defocus: 2.0 µm - 3.2 µm
Nominal magnification: 19500.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Specialist optics
Energy filter
Name:
GATAN GIF 2002
Image Recording
[1]
Detector category:
CCD
Detector model: GATAN MULTISCAN
Number of real images: 26
Average electron dose per image: 80 e/Å2
Bits per pixel: 16.0
Detector model: GATAN MULTISCAN
Number of real images: 26
Average electron dose per image: 80 e/Å2
Bits per pixel: 16.0
Tilt Series
[1]
| Axis 1 | Axis 2 | |||||
|---|---|---|---|---|---|---|
| Min. | Max. | Inc. | Min. | Max. | Inc. | Rotation |
| -60 ° | 60 ° | - | - | - | - | - |
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.7 mm
Nominal defocus: 2.0 µm - 3.2 µm
Nominal magnification: 19500.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.7 mm
Nominal defocus: 2.0 µm - 3.2 µm
Nominal magnification: 19500.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Specialist optics
Energy filter
Name:
GATAN GIF 2002
Image Recording
[1]
Detector category:
CCD
Detector model: GATAN MULTISCAN
Number of real images: 26
Average electron dose per image: 80 e/Å2
Bits per pixel: 16.0
Detector model: GATAN MULTISCAN
Number of real images: 26
Average electron dose per image: 80 e/Å2
Bits per pixel: 16.0
Tilt Series
[1]
| Axis 1 | Axis 2 | |||||
|---|---|---|---|---|---|---|
| Min. | Max. | Inc. | Min. | Max. | Inc. | Rotation |
| -60 ° | 60 ° | - | - | - | - | - |
Details: See materials and methods in relevant publication
Final
reconstruction
Resolution: 40.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
Details:
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
Details:
⌯ Applied Symmetry
Point group:
C2
Software
[1]
| Name | Version | Details |
|---|---|---|
| TOM/AV3, Matlab | - | - |
⦩ Final angle assignment
Details: 0 0 0 in zyz convention
CTF correction
Details: Each tilted image within tomogram
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Sec13/31 complex (as part of complete coat assembled on membrane). Edge, right handed direction
Details: ::::EMDATABANK.org::::EMD-2431::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Sec13/31 complex (as part of complete coat assembled on membrane). Edge, right handed direction
Details: ::::EMDATABANK.org::::EMD-2431::::
⬡ Geometry
| X | Y | Z | |
|---|---|---|---|
| Origin | 0 | 0 | 0 |
| Dimensions (px) | 72 | 72 | 72 |
| Dimensions (Å) | 309.6 | 309.6 | 309.6 |
| Voxel size (Å) | 4.3 | 4.3 | 4.3 |
Contour list
| Primary | Level | Source |
|---|---|---|
| True | 2.0 | AUTHOR |