EMD-1087

Electron Crystallography
7.5 Å
EMD-1087 Deposition: 09/06/2004
Map released: 10/06/2004
Last modified: 02/10/2013
Overview 3D View Sample Experiment Validation Additional data Links
Overview 3D View Sample Experiment Validation Additional data Links

EMD-1087

Three-dimensional structure of the bacterial multidrug transporter EmrE shows it is an asymmetric homodimer.

EMD-1087

Electron Crystallography
7.5 Å
EMD-1087 Deposition: 09/06/2004
Map released: 10/06/2004
Last modified: 02/10/2013
Overview 3D View Sample Experiment Validation Additional data Links
Method: Electron Crystallography
Aggregation State: 2D Array
Specimen preparation [1]
Concentration: 1 mg/mL
Details: 2D crystals were grown in suspension by dialysis
Buffer
pH: 7.5
Details: 20 mM Sodium phosphate pH7.5, 100 mM NaCl, 2mM MgCl2, 1mM EDTA, 1 mM Na azide, 10uM tetraphenylphosphonium
Staining
Type: NEGATIVE
Details: Crystals on carbon support were washed with 1% glucose pH 8 (aq ammonia) containing 25ug/ml bacitracin, 2 times 20ul, and blotted to dryness
Grid
Details: 300 mesh molybdenum grid
Vitrification
Cryogen name: NITROGEN
Chamber humidity: 45%
Chamber temperature: 77 K
Instrument: HOMEMADE PLUNGER
Method: Blot to dryness for 10 seconds before freezing
Details: Vitrification instrument: manual. Performed at room temperature
Crystal formation
Details: 2D crystals were grown in suspension by dialysis
Microscopy [1]
Microscope: FEI TECNAI F30
Illumination mode: SPOT SCAN
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 300 kV
Nominal CS: 2.3 mm
Nominal defocus: 0.2 µm - 1.6 µm
Nominal magnification: 60000.0
Calibrated magnification: 57400.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry liquid nitrogen-cooled cryo specimen holder
Alignment procedure: LEGACY (Astigmatism: objective lens astigmatism was corrected at 200,000 times magnification, Electron beam tilt params: )
Minimum tilt angle: 0
Maximum tilt angle: 46
Temperature
Minimum: 77 K
Average: 77 K
Maximum: 77 K
Image Recording [1]
Detector category: FILM
Detector model: KODAK SO-163 FILM
Scanner: ZEISS SCAI
Sampling interval: 7 µm
Number of real images: 47
Average electron dose per image: 15 e/Å2
Tilt Series [1]
Axis 1 Axis 2
Min. Max. Inc. Min. Max. Inc. Rotation
0 ° 46 ° - - - - -
Image processing [1]
Final reconstruction
Resolution: 7.5 Å ( BY AUTHOR)
Resolution method: OTHER
Algorithm: OTHER
Software [1]
Name Version Details
MRC - -
Crystal parameters
A: 72.1 Å
B: 86.8 Å
γ: 107.3°
Plane group: P 2
CTF correction
Details: CTFFIND2 on each image
Map
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Density map of the asymmetric dimer of EmrE,a multidrug transporter from Escherichia coli
Details: ::::EMDATABANK.org::::EMD-1087::::
Geometry
X Y Z
Origin -2 -63 -10
Dimensions (px) 81 89 21
Dimensions (Å) 72.10005 86.80005 200.0
Voxel size (Å) 0.48066702 0.578667 2.5
Contour list
Primary Level Source
True 59.7 AUTHOR