EMD-0152

Single-particle
3.1 Å
EMD-0152 Deposition: 31/07/2018
Map released: 08/08/2018
Last modified: 28/04/2021
Overview 3D View Sample Experiment Validation Additional data Links
Overview 3D View Sample Experiment Validation Additional data Links

EMD-0152

RELION-3.0 reconstruction of influenza hemagglutinin (HA) trimer using particles from micrographs tilted at 40 degrees in EMPIAR-10097

EMD-0152

Single-particle
3.1 Å
EMD-0152 Deposition: 31/07/2018
Map released: 08/08/2018
Last modified: 28/04/2021
Overview 3D View Sample Experiment Validation Additional data Links
Method: Single-particle
Aggregation State: Particle
Specimen preparation [1]
Concentration: 0.75 mg/mL
Buffer
pH: 7.4
Details: PBS Buffer
Vitrification
Cryogen name: ETHANE
Chamber humidity: 80%
Instrument: GATAN CRYOPLUNGE 3
Details: 3 microliters of 0.75 mg/mL sample was added to a plasma-cleaned (Gatan Solarus) 1.2-micron-hole, 1.3-micron-spacing holey gold grid (made in-house) and plunge-frozen in liquid ethane using the Cryoplunge 3 system (Gatan) operating at 80% humidity, 298K ambient temperature..
Microscopy [1]
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 300 kV
Nominal CS: 2.7 mm
Nominal defocus: 1.0 µm - 3.5 µm
Nominal magnification: 22500.0
Calibrated magnification: 38167.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Cooling holder cryogen: NITROGEN
Details: In order to account for highly preferred orientations of the specimen, data were acquired using tilts of 40 degrees.
Image Recording [1]
Detector model: GATAN K2 SUMMIT (4k x 4k)
Detector mode: COUNTING
Dimensions: 3710 pixel x 3838 pixel
Frames per image: 1-100
Average electron dose per image: 82.0 e/Å2
Image processing [1]
Final reconstruction
Resolution: 3.1 Å ( BY AUTHOR)
Resolution method: FSC 0.143 CUT-OFF
Number of classed used: 1
Number of images used: 151596
Algorithm: FOURIER SPACE
Applied Symmetry
Point group: C3
Software [1]
Name Version Details
RELION 3.0 -
Initial angle assignment
Type: MAXIMUM LIKELIHOOD
Details: RELION SGD
Software [1]
Name Version Details
RELION 3.0 -
Final angle assignment
Type: MAXIMUM LIKELIHOOD
Software [1]
Name Version Details
RELION 3.0 -
Particle selection [1]
Selected Ref. model Method Software Details
608919 - - - -
Final 3D classification
Software [1]
Name Version Details
RELION 3.0 -
CTF correction
Details: Standard CTF correction inside RELION's reconstruction.
Software [2]
Name Version Details
CTFFIND 4.1.10 For initial estimation
RELION 3.0 CTF refinement
Map
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Postprocessed map
Geometry
X Y Z
Origin 0 0 0
Dimensions (px) 216 216 216
Dimensions (Å) 282.96 282.96 282.96
Voxel size (Å) 1.31 1.31 1.31
Contour list
Primary Level Source
True 0.078 AUTHOR