MTBLS143: Comprehensive systems biology analysis of a seven-month cigarette smoke inhalation study in C57BL/6 mice.

Abstract

Smoking of combustible cigarettes has a major impact on human health. Using a systems toxicology approach in a model of chronic obstructive pulmonary disease (C57BL/6 mice), we assessed the health consequences in mice of smoke derived from a prototype modified risk tobacco product (pMRTP) as compared to conventional cigarettes. We investigated physiological and histological endpoints in parallel with transcriptomics, lipidomics, and proteomics profiles in mice exposed to a reference cigarette (3R4F) smoke or a pMRTP aerosol for up to 7 months. We also included a cessation group and a switching-to-pMRTP group (after 2 months of 3R4F exposure) in addition to the control (fresh air-exposed) group, to understand the potential risk reduction of switching to pMRTP compared with continuous 3R4F exposure and cessation.

The dataset shared here describes the lipidomics analyses performed on lung, liver, and plasma of these mice at multiple time points. Lipids were characterized using, in addition to (untargeted) shotgun lipidomics, a set of targeted methods to specifically characterize sphingolipids, ceramides, triglycerides, eicosanoids, and gangliosides.

Click to read more

 Authors: Sam Ansari, Stephanie Boue, Kim Ekroos

  Release date: 19-Nov-2015

 Status: Public

Organism(s)

Mus musculus

  Study Design

CSEO:Lipidomics

CHMO:ultra-performance liquid chromatography-mass spectrometry

NCIT:Tobacco Smoke

NCIT:Cigarette Smoking

CSEO:Modified Risk Tobacco Product

NCIT:Mouse Model

NCIT:Chronic Obstructive Pulmonary Disease

Shotgun lipidomics

targeted metabolites

untargeted metabolites

  Experimental Factors

TreatPhase1

TreatPhase2

ExposureDurationPhase1

ExposureDurationPhase2

TestItemPhase1

TestItemPhase2

Protocol Description
Sample collection Plasma samples were stored at -80 °C prior to analysis. Lungs from 'omics2' mice were perfused through the right ventricle using a 27-G needle with ice-cold 0.9% physiological saline to remove contaminating blood cells. After dissecting the heart, the superior, middle, and post-caval lobes from the right lung were collected and snap-frozen immediately in liquid nitrogen before storing at -80 °C. Similarly, a piece of liver was frozen and stored in the same way. Tissue samples were pulverized with a CP02 CryoPrep Dry Pulverization System (Covaris). Plasma samples were thawed slowly on ice. All samples were homogenized in ice-cold methanol containing 0.1% butyl-hydroxy-toluene (BHT) at a concentration of 100 mg/ml. Homogenized samples were stored at -80 °C prior to lipid extraction and analysis. All lipidomics analyses were performed by Zora Biosciences Oy (Espoo, Finland).
Extraction Lipid Extraction:
Robotic assisted 96-well sample preparation and extraction was performed using a Hamilton Microlab Star system (Hamilton Robotics, Bonaduz, Switzerland). A modified Folch protocol, using chloroform, methanol and acetic acid for liquid-liquid extraction [1], was applied to extract a broad lipid type spectrum [2,3]. This extraction procedure is efficient and robust over a wide lipid concentration range [4]. This method was used to extract glycerolipids, glycerophospholipids, sterol esters and sphingolipids, except for sphingosines and spingosine-1-phosphates which were extracted with 1.1 ml of ice-cold methanol containing 0.1% BHT. The Hamilton robot system was used to extract gangliosides using the methodology described by Fong and colleagues [5] with minor modifications. Eicosanoids were extracted according to the procedure by Deems [6]. Prior to extraction, the samples were spiked with known amounts of internal standards (IS). This set of ISs were used to quantify the endogenous lipids in samples and controls as described below. Following lipid extraction, samples were dried under a gentle stream of nitrogen. Samples for shotgun lipidomics, sphingolipidomics and gangliosides were reconstituted in chloroform:methanol (1:2, v/v), whereas samples for sphingosine/sphingosine-1-phosphate and eicosanoids were reconstituted in methanol. The final extracts were stored at −20 °C upon mass spectrometry analysis.

Ref:
[1] Heiskanen LA, Suoniemi M, Ta HX, Tarasov K, Ekroos K.Long-term performance and stability of molecular shotgun lipidomic analysis of human plasma samples. Anal Chem. 2013 Sep 17; 85(18): 8757-63. PMID: 23919256
[2] Ståhlman M, Ejsing CS, Tarasov K, Perman J, Borén J, Ekroos K. High-throughput shotgun lipidomics by quadrupole time-of-flight mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2009 Sep 15; 877(26): 2664-72. PMID: 19286428
[3] Folch J, Lees M, Sloane Stanley GH. A simple method for the isolation and purification of total lipides from animal tissues. J Biol Chem. 1957 May; 226(1): 497-509. PMID: 13428781
[4] Iverson SJ, Lang SL, Cooper MH. Comparison of the Bligh and Dyer and Folch methods for total lipid determination in a broad range of marine tissue. Lipids. 2001 Nov; 36(11): 1283-7. PMID: 11795862
[5] Fong B, Norris C, Lowe E, McJarrow P. Liquid chromatography-high-resolution mass spectrometry for quantitative analysis of gangliosides. Lipids. 2009 Sep;44(9):867-74. PMID: 19633991
[6] Deems R, Buczynski MW, Bowers-Gentry R, Harkewicz R, Dennis EA. Detection and quantitation of eicosanoids via high performance liquid chromatography-electrospray ionization-mass spectrometry. Methods Enzymol. 2007; 432: 59-82. PMID: 17954213
Chromatography Sphingolipidomics:
Molecular ceramides, glucosylceramides, lactosylceramides and globotriaosylceramides were analyzed as previously described [1]. Briefly, the individual species were separated using an Acquity BEH C18, 2.1 × 50 mm column with a particle size of 1.7 μm (Waters, Milford, MA, USA) assessed on a UHPLC system comprising of a CTC HTC PAL autosampler (CTC Analytics AG, Zwingen, Switzerland) and a Rheos Allegro pump (Flux Instruments, Reinach, Switzerland). A 25 min gradient using 10 mM ammonium acetate in water with 0.1% formic acid (mobile phase A) and 10 mM ammonium acetate in acetonitrile:2-propanol (4:3, v/v) containing 0.1% formic acid (mobile phase B) was used. The column oven temperature was set to 60 °C and a flow rate of 500 µl/min was used.

Sphingosines and sphingosine-1-phosphates were analyzed on a similar system as above. The individual species were separated using an AQUASIL C18, 2.1 x 50 mm column with a particle size of 5 μm (Thermo Fisher Scientific, San Jose, USA). A 19 min gradient using 5 mM ammonium acetate in ultra-pure water (UPW):methanol (1:1) with 0.1% formic acid (mobile phase A), 5 mM ammonium acetate in methanol with 0.1% formic acid (mobile phase B) and 10 mM ammonium acetate in isopropanol with 0.1% formic acid (mobile phase C) was used. The column oven temperature was set to 60 °C and a flow rate of 750 µl/min was used.

Ganglioside lipidomics:
Gangliosides were analyzed as described previously [2], except that 10 mM ammonium acetate and 0.1% formic acid were used in all solvents instead of ammonium formate. The analysis was assessed on a 6500 QTRAP (Sciex, Concord, Canada) equipped with a similar UHPLC system as described above. The individual species were separated using an Acquity BEH C18, 2.1 × 50 mm column with a particle size of 1.7 μm (Waters, Milford, MA, USA). A 32 min gradient using 10 mM ammonium acetate in methanol with 0.1% formic acid (mobile phase A), 10 mM ammonium acetate in isopropanol with 0.1% formic acid (mobile phase B) and 10 mM ammonium acetate in HPLC grade water with 0.1% formic acid (mobile phase C) was used. The column oven temperature was set to 45 °C and a flow rate of 500 µl/min was used.

Eicosanoid lipidomics:
Eicosanoids were analyzed as described previously [3]. A similar instrument setup as for sphingolipidomics was used. The individual species were separated using a Phenomenex Jupiter, 250 × 2.0 mm column with a particle size of 5 μm (Phenomenex, Torrance, CA, USA). A 18 min gradient using water:acetonitrile:formic acid (63:37:0.02) (mobile phase A) and acetonitrile:isopropanol (50:50) (mobile phase B) was used. The column oven temperature was set to 60 °C and a flow rate of 300 µl/min was used.

Ref:
[1] Merrill AH Jr, Sullards MC, Allegood JC, Kelly S, Wang E. Sphingolipidomics: high-throughput, structure-specific, and quantitative analysis of sphingolipids by liquid chromatography tandem mass spectrometry. Methods. 2005 Jun; 36(2): 207-24. PMID: 15894491
[2] Ikeda K1, Shimizu T, Taguchi R. Targeted analysis of ganglioside and sulfatide molecular species by LC/ESI-MS/MS with theoretically expanded multiple reaction monitoring. J Lipid Res. 2008 Dec; 49(12): 2678-89. PMID: 18703820
[3] Deems R, Buczynski MW, Bowers-Gentry R, Harkewicz R, Dennis EA.Detection and quantitation of eicosanoids via high performance liquid chromatography-electrospray ionization-mass spectrometry. Methods Enzymol. 2007; 432: 59-82. PMID: 17954213
Mass spectrometry Shotgun Lipidomics:
Shotgun lipidomics was carried on a QTRAP 5500 (Sciex). Quantification of molecular glycerolipids, glycerophosopholipids and sterol esters was assessed by shotgun lipidomics as previously described [1]. Samples were loaded into 96-well plates (twin.tec PCR Plate 96, Eppendorf AG, Hamburg, Germany) and sealed with an aluminium foil (Heatsealing Foil, Eppendorf AG). Aliquots of 10 µl were aspirated and infused. Precursor ion and neutral loss scans were carried out in positive and negative ion modes, as described previously [2-4]. On the TriVersa NanoMate electrospray ionization (ESI) voltages applied were typically 1.3 kV and -1.3 kV in positive and negative ion modes respectively. The gas pressure was set typically to 0.75 psi in both polarity modes. In the positive ion mode the following MS settings were used: curtain gas; 20, collision gas; 6, interface heater; 60, declustering potential; 30, entrance potential 10 and collision cell exit potential; 20. In negative ion mode the following settings were used: curtain gas; 20, collision gas; 6, interface heater; 60, declustering potential; -100, entrance potential -10 and collision cell exit potential; -20. Q1 and Q3 quadrupoles were operated in unit resolution mode.

Sphingolipidomics:
A QTRAP 5500 mass spectrometer (Sciex, Concord, Canada) equipped with an electrospray ion source, was used for mass spectrometric determination. The instrument was operated in multiple reaction monitoring (MRM) mode in positive ion mode as previously described [5]. 78 MRM transitions were monitored using a dwell time of 20 ms. Q1 and Q3 quadrupoles were operated in unit resolution mode. The collision energy was set at 40 eV for ceramides, 45 eV for glucosyl- and lactosylceramides and 66 eV for globotriaosylceramides. Nitrogen was used as collision gas. The ESI voltage was set at 5000 V and the ion source temperature at 400 °C.

For sphingosines and sphingosine-1-phosphates, the individual species were monitored in multiple reaction monitoring (MRM) mode in positive ion mode. 22 MRM transitions were monitored using a dwell time of 25 ms. Q1 and Q3 quadrupoles were operated in unit resolution mode. The collision energy was set at 22 eV for sphingosines and 21 eV for sphingosine-1-phosphates. Nitrogen was used as collision gas. The ESI voltage was set at 4500 V and the ion source temperature at 550 °C.

Ganglioside lipidomics:
The analysis was assessed on a QTRAP 6500 (Sciex, Concord, Canada) equipped with a similar UHPLC system. The individual species were monitored in multiple reaction monitoring (MRM) mode in negative ion mode. 103 MRM transitions were monitored using a dwell time of 30 ms. Q1 and Q3 quadrupoles were operated in unit resolution mode. The collision energy was set at 80 eV for GM1s, 70 eV for GM2s, 60 eV for GM3s, 50 eV for GDs, and 40 eV for GQs and GTs. Nitrogen was used as collision gas. The ESI voltage was set at -4500 V and the ion source temperature at 400 °C.

Eicosanoid lipidomics:
The analysis was assessed on a QTRAP 5500 (Sciex, Concord, Canada). The individual species were monitored in multiple reaction monitoring (MRM) mode in negative ion mode. 103 MRM transitions, split in two runs, were monitored using a dwell time of 15 ms. Q1 and Q3 quadrupoles were operated in unit resolution mode. The collision energy was set according to Deems et. al. [6]. Nitrogen was used as collision gas. The ESI voltage was set at -4500 V and the ion source temperature at 525 °C.

Ref:
[1] Heiskanen LA, Suoniemi M, Ta HX, Tarasov K, Ekroos K. Long-term performance and stability of molecular shotgun lipidomic analysis of human plasma samples. Anal Chem. 2013 Sep 17; 85(18): 8757-63. PMID: 23919256
[2] Ekroos K, Chernushevich IV, Simons K, Shevchenko A. Quantitative profiling of phospholipids by multiple precursor ion scanning on a hybrid quadrupole time-of-flight mass spectrometer. Anal Chem. 2002 Mar 1; 74(5): 941-9. PMID: 11924996
[3] Ekroos K, Ejsing CS, Bahr U, Karas M, Simons K, Shevchenko A. Charting molecular composition of phosphatidylcholines by fatty acid scanning and ion trap MS3 fragmentation. J Lipid Res. 2003 Nov; 44(11): 2181-92. PMID:12923235
[4] Liebisch G, Binder M, Schifferer R, Langmann T, Schulz B, Schmitz G. High throughput quantification of cholesterol and cholesteryl ester by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Biochim Biophys Acta. 2006 Jan; 1761(1): 121-8. PMID: 16458590
[5] Merrill AH Jr, Sullards MC, Allegood JC, Kelly S, Wang E. Sphingolipidomics: high-throughput, structure-specific, and quantitative analysis of sphingolipids by liquid chromatography tandem mass spectrometry. Methods. 2005 Jun; 36(2): 207-24. PMID: 15894491
[6] Deems R, Buczynski MW, Bowers-Gentry R, Harkewicz R, Dennis EA. Detection and quantitation of eicosanoids via high performance liquid chromatography-electrospray ionization-mass spectrometry. Methods Enzymol. 2007; 432: 59-82. PMID: 17954213
Data transformation Samples from 2 month and 3 month time points were analyzed separately from 7 month time point. Variation in instrument control samples between the batches were observed in ceramide (Cer, LacCer, Glc/GalCer and Gb3 lipid classes) and eicosanoid lipidomics platforms, and therefore correction factors were applied to endogenous lipid concentrations of these platforms.

Due to the use of correction factors, the ceramide and eicosanoid concentrations at 7 month time point are relative instead of absolute. Group comparisons within a particular time point are not affected by the use of correction factors.

The variation of endogenous lipid concentrations was due to internal standard (IS) issues (eicosanoids) and variation in total lipid extraction (ceramide species). The eicosanoid IS concentrations were varying between the two batches, which was observed from control samples. Variation was most likely due to evaporation of solvent from the IS vials, even though the vials were unopened and stored as recommended by the manufacturer.

The correction factors were calculated based on instrument control samples (ICs), which are included in all extractions to monitor quality of the lipidomics analysis. Pooled human plasma is extracted in ICs instead of a sample, concentrations of ISs are the same as in samples, and the extraction is done in the same fashion for ICs and samples. Ten replicate ICs were run per one sample set.

Endogenous lipid concentrations of eicosanoids and ceramide lipid species on 7 months' time point samples were corrected by correction factors (k) obtained from the following equation. Peak area ratios (Endogenous area / IS area) from ten replicate IC runs were first calculated, and then averages of these ten ratios were used for determine the correction factors according to the equation. Obviously, the correction factors were determined only to those lipids, which were detected in IC. For ceramide species the calculation was done per lipid extraction of the tissue type, for example ICs in lung sample batches were compared with each other.

To calculate corrected concentration IS amount (pmol) in a sample was multiplied by k.
Metabolite identification The mass spectrometry data files were processed using LipidView™ V1.0.99 and MultiQuant™ 2.0 softwares to generate a list of lipid names and peak areas. Shotgun lipidomics data was processed in LipidView™ as described previously [1]. Briefly, the endogenous species were identified based on their characteristic fragment ions, neutral losses and parent ions. For instance, m/z 184.1 which is the characteristic headgroup ion of phosphatidylcholines (PC) and sphingomyelins (SM) [2] was used to identify together with the parent mass the peaks observed in the mass spectrum of PIS 184.1 in positive ion mode. In a similar way the monitored acyl ions were utilized to identify the molecular species in negative ion mode [3]. For instance, identification of PC 16:0-18:1 requires corresponding signals from both the 16:0 (PIS of m/z 255.2) and the 18:1 (PIS of m/z 281.2) scans.

MRM data was processed in MultiQuant™. The selected lipid characteristic ions and their parent masses in conjunction with retention time were used for the identification of the endogenous species. Information dependent acquisition (IDA) experiments were used for confirming identifications. MRM was used as survey scan to trigger the IDA, followed by enhanced product ion (EPI) scans of two most intense ions.

The identified lipids were quantified by normalizing against their respective internal standard and matrix type, e.g. volume for plasma, and presented accordingly (e.g. µM for plasma). Total lipid class concentrations were calculated by summing-up the concentrations of species belonging to the same class. Molar distribution percentages were generated by dividing all the observed lipid concentrations to the class total concentration within the sample.

Data filtering of the final data set was based on the frequency of individual lipid molecules observed throughout the collected data. Molecules observed from less than 75% of the samples, and molecules lacking lipid class specific internal standards were excluded. Molecules having four fold lower or higher concentration than the median of the group was considered as an outlier and excluded. Filtering procedures were performed separately for both polarity modes and lipidomic assessment, prior to merging of the final lipidomic data set. All the calculations and data processing were performed using SAS 9.3 (SAS Institute).

Ref:
[1] Ejsing CS, Duchoslav E, Sampaio J, Simons K, Bonner R, Thiele C, Ekroos K, Shevchenko A. Automated identification and quantification of glycerophospholipid molecular species by multiple precursor ion scanning. Anal Chem. 2006 Sep 1; 78(17):6202-14.
[2] Brügger B, Erben G, Sandhoff R, Wieland FT, Lehmann WD. Quantitative analysis of biological membrane lipids at the low picomole level by nano-electrospray ionization tandem mass spectrometry. Proc Natl Acad Sci U S A. 1997 Mar 18; 94(6): 2339-44. PMID: 9122196
[3] Ekroos K, Ejsing CS, Bahr U, Karas M, Simons K, Shevchenko A. Charting molecular composition of phosphatidylcholines by fatty acid scanning and ion trap MS3 fragmentation. J Lipid Res. 2003 Nov;44(11):2181-92. PMID: 12923235.
Source Name Organism Variant Organism part Protocol REF Sample Name TreatPhase1 TestItemPhase1 ExposureDurationPhase1 Unit TreatPhase2 TestItemPhase2 ExposureDurationPhase2 Unit
920025 Mus musculus C57BL/6 liver Sample collection 920025-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920025 Mus musculus C57BL/6 lung Sample collection 920025-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920031 Mus musculus C57BL/6 blood plasma Sample collection 920031-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920037 Mus musculus C57BL/6 liver Sample collection 920037-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920037 Mus musculus C57BL/6 lung Sample collection 920037-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920043 Mus musculus C57BL/6 liver Sample collection 920043-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920043 Mus musculus C57BL/6 lung Sample collection 920043-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920046 Mus musculus C57BL/6 blood plasma Sample collection 920046-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920050 Mus musculus C57BL/6 blood plasma Sample collection 920050-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920052 Mus musculus C57BL/6 blood plasma Sample collection 920052-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920056 Mus musculus C57BL/6 liver Sample collection 920056-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920056 Mus musculus C57BL/6 lung Sample collection 920056-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920067 Mus musculus C57BL/6 liver Sample collection 920067-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920067 Mus musculus C57BL/6 lung Sample collection 920067-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920092 Mus musculus C57BL/6 liver Sample collection 920092-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920092 Mus musculus C57BL/6 lung Sample collection 920092-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920093 Mus musculus C57BL/6 liver Sample collection 920093-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920093 Mus musculus C57BL/6 lung Sample collection 920093-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920100 Mus musculus C57BL/6 liver Sample collection 920100-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920100 Mus musculus C57BL/6 lung Sample collection 920100-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920109 Mus musculus C57BL/6 blood plasma Sample collection 920109-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920113 Mus musculus C57BL/6 liver Sample collection 920113-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920113 Mus musculus C57BL/6 lung Sample collection 920113-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920115 Mus musculus C57BL/6 blood plasma Sample collection 920115-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920116 Mus musculus C57BL/6 liver Sample collection 920116-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920116 Mus musculus C57BL/6 lung Sample collection 920116-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920128 Mus musculus C57BL/6 blood plasma Sample collection 920128-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920146 Mus musculus C57BL/6 liver Sample collection 920146-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920146 Mus musculus C57BL/6 lung Sample collection 920146-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920157 Mus musculus C57BL/6 blood plasma Sample collection 920157-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920174 Mus musculus C57BL/6 liver Sample collection 920174-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920174 Mus musculus C57BL/6 lung Sample collection 920174-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920175 Mus musculus C57BL/6 blood plasma Sample collection 920175-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920179 Mus musculus C57BL/6 blood plasma Sample collection 920179-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920186 Mus musculus C57BL/6 liver Sample collection 920186-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920186 Mus musculus C57BL/6 lung Sample collection 920186-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920204 Mus musculus C57BL/6 blood plasma Sample collection 920204-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920208 Mus musculus C57BL/6 liver Sample collection 920208-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920208 Mus musculus C57BL/6 lung Sample collection 920208-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920216 Mus musculus C57BL/6 blood plasma Sample collection 920216-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920223 Mus musculus C57BL/6 liver Sample collection 920223-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920223 Mus musculus C57BL/6 lung Sample collection 920223-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920224 Mus musculus C57BL/6 liver Sample collection 920224-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920224 Mus musculus C57BL/6 lung Sample collection 920224-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920229 Mus musculus C57BL/6 blood plasma Sample collection 920229-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920243 Mus musculus C57BL/6 liver Sample collection 920243-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920243 Mus musculus C57BL/6 lung Sample collection 920243-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920250 Mus musculus C57BL/6 blood plasma Sample collection 920250-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920264 Mus musculus C57BL/6 blood plasma Sample collection 920264-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920265 Mus musculus C57BL/6 blood plasma Sample collection 920265-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920268 Mus musculus C57BL/6 liver Sample collection 920268-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920268 Mus musculus C57BL/6 lung Sample collection 920268-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920274 Mus musculus C57BL/6 liver Sample collection 920274-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920274 Mus musculus C57BL/6 lung Sample collection 920274-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920279 Mus musculus C57BL/6 liver Sample collection 920279-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920279 Mus musculus C57BL/6 lung Sample collection 920279-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920280 Mus musculus C57BL/6 liver Sample collection 920280-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920280 Mus musculus C57BL/6 lung Sample collection 920280-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920281 Mus musculus C57BL/6 blood plasma Sample collection 920281-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920300 Mus musculus C57BL/6 liver Sample collection 920300-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920300 Mus musculus C57BL/6 lung Sample collection 920300-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920302 Mus musculus C57BL/6 blood plasma Sample collection 920302-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920303 Mus musculus C57BL/6 liver Sample collection 920303-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920303 Mus musculus C57BL/6 lung Sample collection 920303-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920323 Mus musculus C57BL/6 blood plasma Sample collection 920323-Blood-extract Conditioned Fresh Air 2 month month
920327 Mus musculus C57BL/6 liver Sample collection 920327-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920327 Mus musculus C57BL/6 lung Sample collection 920327-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920339 Mus musculus C57BL/6 blood plasma Sample collection 920339-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920346 Mus musculus C57BL/6 blood plasma Sample collection 920346-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920360 Mus musculus C57BL/6 blood plasma Sample collection 920360-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920368 Mus musculus C57BL/6 liver Sample collection 920368-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920368 Mus musculus C57BL/6 lung Sample collection 920368-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920374 Mus musculus C57BL/6 liver Sample collection 920374-Liver-extract Conditioned Fresh Air 2 month month
920374 Mus musculus C57BL/6 lung Sample collection 920374-Rightlung-extract Conditioned Fresh Air 2 month month
920375 Mus musculus C57BL/6 blood plasma Sample collection 920375-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920377 Mus musculus C57BL/6 blood plasma Sample collection 920377-Blood-extract Conditioned Fresh Air 2 month month
920383 Mus musculus C57BL/6 blood plasma Sample collection 920383-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920386 Mus musculus C57BL/6 blood plasma Sample collection 920386-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920393 Mus musculus C57BL/6 blood plasma Sample collection 920393-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920399 Mus musculus C57BL/6 liver Sample collection 920399-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920399 Mus musculus C57BL/6 lung Sample collection 920399-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920404 Mus musculus C57BL/6 blood plasma Sample collection 920404-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920412 Mus musculus C57BL/6 liver Sample collection 920412-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920412 Mus musculus C57BL/6 lung Sample collection 920412-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920414 Mus musculus C57BL/6 blood plasma Sample collection 920414-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920416 Mus musculus C57BL/6 liver Sample collection 920416-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920416 Mus musculus C57BL/6 lung Sample collection 920416-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920417 Mus musculus C57BL/6 blood plasma Sample collection 920417-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920418 Mus musculus C57BL/6 blood plasma Sample collection 920418-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920421 Mus musculus C57BL/6 liver Sample collection 920421-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920421 Mus musculus C57BL/6 lung Sample collection 920421-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920427 Mus musculus C57BL/6 blood plasma Sample collection 920427-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920430 Mus musculus C57BL/6 blood plasma Sample collection 920430-Blood-extract Conditioned Fresh Air 2 month month
920441 Mus musculus C57BL/6 blood plasma Sample collection 920441-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920455 Mus musculus C57BL/6 blood plasma Sample collection 920455-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920456 Mus musculus C57BL/6 blood plasma Sample collection 920456-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920460 Mus musculus C57BL/6 liver Sample collection 920460-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920460 Mus musculus C57BL/6 lung Sample collection 920460-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920462 Mus musculus C57BL/6 liver Sample collection 920462-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920462 Mus musculus C57BL/6 lung Sample collection 920462-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920478 Mus musculus C57BL/6 blood plasma Sample collection 920478-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920480 Mus musculus C57BL/6 blood plasma Sample collection 920480-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920484 Mus musculus C57BL/6 liver Sample collection 920484-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920484 Mus musculus C57BL/6 lung Sample collection 920484-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920513 Mus musculus C57BL/6 blood plasma Sample collection 920513-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920524 Mus musculus C57BL/6 blood plasma Sample collection 920524-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920527 Mus musculus C57BL/6 blood plasma Sample collection 920527-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920531 Mus musculus C57BL/6 liver Sample collection 920531-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920531 Mus musculus C57BL/6 lung Sample collection 920531-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920538 Mus musculus C57BL/6 blood plasma Sample collection 920538-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920540 Mus musculus C57BL/6 blood plasma Sample collection 920540-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920541 Mus musculus C57BL/6 blood plasma Sample collection 920541-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920548 Mus musculus C57BL/6 blood plasma Sample collection 920548-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920553 Mus musculus C57BL/6 liver Sample collection 920553-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920553 Mus musculus C57BL/6 lung Sample collection 920553-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920563 Mus musculus C57BL/6 blood plasma Sample collection 920563-Blood-extract Conditioned Fresh Air 2 month month
920564 Mus musculus C57BL/6 blood plasma Sample collection 920564-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920570 Mus musculus C57BL/6 blood plasma Sample collection 920570-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920573 Mus musculus C57BL/6 blood plasma Sample collection 920573-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920587 Mus musculus C57BL/6 liver Sample collection 920587-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920587 Mus musculus C57BL/6 lung Sample collection 920587-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920590 Mus musculus C57BL/6 liver Sample collection 920590-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920590 Mus musculus C57BL/6 lung Sample collection 920590-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920602 Mus musculus C57BL/6 liver Sample collection 920602-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920602 Mus musculus C57BL/6 lung Sample collection 920602-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920604 Mus musculus C57BL/6 liver Sample collection 920604-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920604 Mus musculus C57BL/6 lung Sample collection 920604-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920605 Mus musculus C57BL/6 liver Sample collection 920605-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920605 Mus musculus C57BL/6 lung Sample collection 920605-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920612 Mus musculus C57BL/6 blood plasma Sample collection 920612-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920616 Mus musculus C57BL/6 liver Sample collection 920616-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920616 Mus musculus C57BL/6 lung Sample collection 920616-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920619 Mus musculus C57BL/6 blood plasma Sample collection 920619-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920621 Mus musculus C57BL/6 liver Sample collection 920621-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920621 Mus musculus C57BL/6 lung Sample collection 920621-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920622 Mus musculus C57BL/6 blood plasma Sample collection 920622-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920630 Mus musculus C57BL/6 liver Sample collection 920630-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920630 Mus musculus C57BL/6 lung Sample collection 920630-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920635 Mus musculus C57BL/6 blood plasma Sample collection 920635-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920642 Mus musculus C57BL/6 blood plasma Sample collection 920642-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920645 Mus musculus C57BL/6 liver Sample collection 920645-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920645 Mus musculus C57BL/6 lung Sample collection 920645-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920657 Mus musculus C57BL/6 blood plasma Sample collection 920657-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920664 Mus musculus C57BL/6 liver Sample collection 920664-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920664 Mus musculus C57BL/6 lung Sample collection 920664-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920673 Mus musculus C57BL/6 liver Sample collection 920673-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920673 Mus musculus C57BL/6 lung Sample collection 920673-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920694 Mus musculus C57BL/6 blood plasma Sample collection 920694-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920696 Mus musculus C57BL/6 liver Sample collection 920696-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920696 Mus musculus C57BL/6 lung Sample collection 920696-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920698 Mus musculus C57BL/6 blood plasma Sample collection 920698-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920700 Mus musculus C57BL/6 liver Sample collection 920700-Liver-extract Conditioned Fresh Air 2 month month
920700 Mus musculus C57BL/6 lung Sample collection 920700-Rightlung-extract Conditioned Fresh Air 2 month month
920705 Mus musculus C57BL/6 liver Sample collection 920705-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920705 Mus musculus C57BL/6 lung Sample collection 920705-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920711 Mus musculus C57BL/6 liver Sample collection 920711-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920711 Mus musculus C57BL/6 lung Sample collection 920711-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920712 Mus musculus C57BL/6 liver Sample collection 920712-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920712 Mus musculus C57BL/6 lung Sample collection 920712-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920728 Mus musculus C57BL/6 blood plasma Sample collection 920728-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920736 Mus musculus C57BL/6 liver Sample collection 920736-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920736 Mus musculus C57BL/6 lung Sample collection 920736-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920738 Mus musculus C57BL/6 blood plasma Sample collection 920738-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920741 Mus musculus C57BL/6 liver Sample collection 920741-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920741 Mus musculus C57BL/6 lung Sample collection 920741-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920751 Mus musculus C57BL/6 liver Sample collection 920751-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920751 Mus musculus C57BL/6 lung Sample collection 920751-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920763 Mus musculus C57BL/6 liver Sample collection 920763-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920763 Mus musculus C57BL/6 lung Sample collection 920763-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920768 Mus musculus C57BL/6 blood plasma Sample collection 920768-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920770 Mus musculus C57BL/6 liver Sample collection 920770-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920770 Mus musculus C57BL/6 lung Sample collection 920770-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920776 Mus musculus C57BL/6 liver Sample collection 920776-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920776 Mus musculus C57BL/6 lung Sample collection 920776-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920778 Mus musculus C57BL/6 blood plasma Sample collection 920778-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920779 Mus musculus C57BL/6 liver Sample collection 920779-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920779 Mus musculus C57BL/6 lung Sample collection 920779-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920788 Mus musculus C57BL/6 blood plasma Sample collection 920788-Blood-extract Conditioned Fresh Air 2 month month
920790 Mus musculus C57BL/6 blood plasma Sample collection 920790-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920791 Mus musculus C57BL/6 blood plasma Sample collection 920791-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920794 Mus musculus C57BL/6 liver Sample collection 920794-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920794 Mus musculus C57BL/6 lung Sample collection 920794-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920796 Mus musculus C57BL/6 liver Sample collection 920796-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920796 Mus musculus C57BL/6 lung Sample collection 920796-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920810 Mus musculus C57BL/6 blood plasma Sample collection 920810-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920818 Mus musculus C57BL/6 liver Sample collection 920818-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920818 Mus musculus C57BL/6 lung Sample collection 920818-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920833 Mus musculus C57BL/6 blood plasma Sample collection 920833-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920843 Mus musculus C57BL/6 liver Sample collection 920843-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920843 Mus musculus C57BL/6 lung Sample collection 920843-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920857 Mus musculus C57BL/6 liver Sample collection 920857-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920857 Mus musculus C57BL/6 lung Sample collection 920857-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920861 Mus musculus C57BL/6 blood plasma Sample collection 920861-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920863 Mus musculus C57BL/6 blood plasma Sample collection 920863-Blood-extract Conditioned Fresh Air 2 month month
920880 Mus musculus C57BL/6 liver Sample collection 920880-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920880 Mus musculus C57BL/6 lung Sample collection 920880-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920881 Mus musculus C57BL/6 blood plasma Sample collection 920881-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920885 Mus musculus C57BL/6 liver Sample collection 920885-Liver-extract Conditioned Fresh Air 2 month month
920885 Mus musculus C57BL/6 lung Sample collection 920885-Rightlung-extract Conditioned Fresh Air 2 month month
920888 Mus musculus C57BL/6 liver Sample collection 920888-Liver-extract Conditioned Fresh Air 2 month month
920888 Mus musculus C57BL/6 lung Sample collection 920888-Rightlung-extract Conditioned Fresh Air 2 month month
920893 Mus musculus C57BL/6 blood plasma Sample collection 920893-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920896 Mus musculus C57BL/6 blood plasma Sample collection 920896-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920899 Mus musculus C57BL/6 liver Sample collection 920899-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920899 Mus musculus C57BL/6 lung Sample collection 920899-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920902 Mus musculus C57BL/6 liver Sample collection 920902-Liver-extract Conditioned Fresh Air 2 month month
920902 Mus musculus C57BL/6 lung Sample collection 920902-Rightlung-extract Conditioned Fresh Air 2 month month
920903 Mus musculus C57BL/6 blood plasma Sample collection 920903-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
920906 Mus musculus C57BL/6 liver Sample collection 920906-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920906 Mus musculus C57BL/6 lung Sample collection 920906-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
920907 Mus musculus C57BL/6 blood plasma Sample collection 920907-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920908 Mus musculus C57BL/6 liver Sample collection 920908-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920908 Mus musculus C57BL/6 lung Sample collection 920908-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920922 Mus musculus C57BL/6 liver Sample collection 920922-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920922 Mus musculus C57BL/6 lung Sample collection 920922-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920923 Mus musculus C57BL/6 blood plasma Sample collection 920923-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920933 Mus musculus C57BL/6 blood plasma Sample collection 920933-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
920939 Mus musculus C57BL/6 blood plasma Sample collection 920939-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920941 Mus musculus C57BL/6 liver Sample collection 920941-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920941 Mus musculus C57BL/6 lung Sample collection 920941-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920942 Mus musculus C57BL/6 liver Sample collection 920942-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920942 Mus musculus C57BL/6 lung Sample collection 920942-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920947 Mus musculus C57BL/6 blood plasma Sample collection 920947-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920952 Mus musculus C57BL/6 liver Sample collection 920952-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920952 Mus musculus C57BL/6 lung Sample collection 920952-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
920959 Mus musculus C57BL/6 blood plasma Sample collection 920959-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920966 Mus musculus C57BL/6 blood plasma Sample collection 920966-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
920981 Mus musculus C57BL/6 liver Sample collection 920981-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920981 Mus musculus C57BL/6 lung Sample collection 920981-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
920983 Mus musculus C57BL/6 liver Sample collection 920983-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920983 Mus musculus C57BL/6 lung Sample collection 920983-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920984 Mus musculus C57BL/6 blood plasma Sample collection 920984-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
920987 Mus musculus C57BL/6 blood plasma Sample collection 920987-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
920988 Mus musculus C57BL/6 blood plasma Sample collection 920988-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
920993 Mus musculus C57BL/6 liver Sample collection 920993-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
920993 Mus musculus C57BL/6 lung Sample collection 920993-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
921001 Mus musculus C57BL/6 liver Sample collection 921001-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921001 Mus musculus C57BL/6 lung Sample collection 921001-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921007 Mus musculus C57BL/6 blood plasma Sample collection 921007-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921011 Mus musculus C57BL/6 blood plasma Sample collection 921011-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921013 Mus musculus C57BL/6 blood plasma Sample collection 921013-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921017 Mus musculus C57BL/6 liver Sample collection 921017-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921017 Mus musculus C57BL/6 lung Sample collection 921017-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921020 Mus musculus C57BL/6 blood plasma Sample collection 921020-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921037 Mus musculus C57BL/6 liver Sample collection 921037-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921037 Mus musculus C57BL/6 lung Sample collection 921037-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921047 Mus musculus C57BL/6 blood plasma Sample collection 921047-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
921048 Mus musculus C57BL/6 blood plasma Sample collection 921048-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921057 Mus musculus C57BL/6 liver Sample collection 921057-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
921057 Mus musculus C57BL/6 lung Sample collection 921057-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
921061 Mus musculus C57BL/6 blood plasma Sample collection 921061-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
921062 Mus musculus C57BL/6 liver Sample collection 921062-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
921062 Mus musculus C57BL/6 lung Sample collection 921062-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
921067 Mus musculus C57BL/6 liver Sample collection 921067-Liver-extract Conditioned Fresh Air 2 month month
921067 Mus musculus C57BL/6 lung Sample collection 921067-Rightlung-extract Conditioned Fresh Air 2 month month
921081 Mus musculus C57BL/6 liver Sample collection 921081-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
921081 Mus musculus C57BL/6 lung Sample collection 921081-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
921086 Mus musculus C57BL/6 liver Sample collection 921086-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921086 Mus musculus C57BL/6 lung Sample collection 921086-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921089 Mus musculus C57BL/6 liver Sample collection 921089-Liver-extract Conditioned Fresh Air 2 month month
921089 Mus musculus C57BL/6 lung Sample collection 921089-Rightlung-extract Conditioned Fresh Air 2 month month
921101 Mus musculus C57BL/6 blood plasma Sample collection 921101-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921109 Mus musculus C57BL/6 blood plasma Sample collection 921109-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921113 Mus musculus C57BL/6 liver Sample collection 921113-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
921113 Mus musculus C57BL/6 lung Sample collection 921113-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
921114 Mus musculus C57BL/6 liver Sample collection 921114-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
921114 Mus musculus C57BL/6 lung Sample collection 921114-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
921128 Mus musculus C57BL/6 liver Sample collection 921128-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921128 Mus musculus C57BL/6 lung Sample collection 921128-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921132 Mus musculus C57BL/6 liver Sample collection 921132-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
921132 Mus musculus C57BL/6 lung Sample collection 921132-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
921134 Mus musculus C57BL/6 liver Sample collection 921134-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921134 Mus musculus C57BL/6 lung Sample collection 921134-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921138 Mus musculus C57BL/6 blood plasma Sample collection 921138-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921139 Mus musculus C57BL/6 liver Sample collection 921139-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921139 Mus musculus C57BL/6 lung Sample collection 921139-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921140 Mus musculus C57BL/6 blood plasma Sample collection 921140-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921147 Mus musculus C57BL/6 blood plasma Sample collection 921147-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921152 Mus musculus C57BL/6 blood plasma Sample collection 921152-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month month
921159 Mus musculus C57BL/6 liver Sample collection 921159-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921159 Mus musculus C57BL/6 lung Sample collection 921159-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921166 Mus musculus C57BL/6 liver Sample collection 921166-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921166 Mus musculus C57BL/6 lung Sample collection 921166-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921169 Mus musculus C57BL/6 blood plasma Sample collection 921169-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921173 Mus musculus C57BL/6 liver Sample collection 921173-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921173 Mus musculus C57BL/6 lung Sample collection 921173-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 5 month
921177 Mus musculus C57BL/6 liver Sample collection 921177-Liver-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921177 Mus musculus C57BL/6 lung Sample collection 921177-Rightlung-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921183 Mus musculus C57BL/6 liver Sample collection 921183-Liver-extract Conditioned Fresh Air 2 month month
921183 Mus musculus C57BL/6 lung Sample collection 921183-Rightlung-extract Conditioned Fresh Air 2 month month
921196 Mus musculus C57BL/6 blood plasma Sample collection 921196-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921200 Mus musculus C57BL/6 blood plasma Sample collection 921200-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
921262 Mus musculus C57BL/6 liver Sample collection 921262-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921262 Mus musculus C57BL/6 lung Sample collection 921262-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 1 month
921276 Mus musculus C57BL/6 liver Sample collection 921276-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921276 Mus musculus C57BL/6 lung Sample collection 921276-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 1 month
921277 Mus musculus C57BL/6 blood plasma Sample collection 921277-Blood-extract Conditioned Fresh Air 2 month month
921278 Mus musculus C57BL/6 blood plasma Sample collection 921278-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month
921286 Mus musculus C57BL/6 liver Sample collection 921286-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
921286 Mus musculus C57BL/6 lung Sample collection 921286-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 5 month
921294 Mus musculus C57BL/6 blood plasma Sample collection 921294-Blood-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month month
921296 Mus musculus C57BL/6 liver Sample collection 921296-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
921296 Mus musculus C57BL/6 lung Sample collection 921296-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Conditioned Fresh Air 1 month
921297 Mus musculus C57BL/6 liver Sample collection 921297-Liver-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
921297 Mus musculus C57BL/6 lung Sample collection 921297-Rightlung-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
921304 Mus musculus C57BL/6 liver Sample collection 921304-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921304 Mus musculus C57BL/6 lung Sample collection 921304-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921312 Mus musculus C57BL/6 blood plasma Sample collection 921312-Blood-extract Conditioned Fresh Air 2 month Conditioned Fresh Air 5 month
921318 Mus musculus C57BL/6 liver Sample collection 921318-Liver-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921318 Mus musculus C57BL/6 lung Sample collection 921318-Rightlung-extract Diluted Mainstream Cigarette Smoke 3R4F 2 month Diluted Mainstream Cigarette Smoke 3R4F 5 month
921319 Mus musculus C57BL/6 blood plasma Sample collection 921319-Blood-extract Conditioned Fresh Air 2 month month
921321 Mus musculus C57BL/6 blood plasma Sample collection 921321-Blood-extract Diluted Mainstream Cigarette Smoke pMRTP 2 month Diluted Mainstream Cigarette Smoke pMRTP 1 month

Assay  1

Assay file name: a_mtbls143_SPH_mass_spectrometry.txt
Technology: mass spectrometry
Platform: QTRAP 5500 (Applied Biosystems)

Instrumentation

Sample Name Protocol REF Post Extraction Derivatization Extract Name Protocol REF Chromatography Instrument Autosampler model Column model Column type Labeled Extract Name Label Protocol REF Scan polarity Scan m/z range Instrument Ion source Mass analyzer MS Assay Name Raw Spectral Data File Protocol REF Normalization Name Derived Spectral Data File Protocol REF Data Transformation Name Metabolite Assignment File
920031-Blood-extract Extraction other 920031-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920031-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920037-Rightlung-extract Extraction other 920037-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920037-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920046-Blood-extract Extraction other 920046-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920046-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920050-Blood-extract Extraction other 920050-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920050-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920052-Blood-extract Extraction other 920052-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920052-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920056-Rightlung-extract Extraction other 920056-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920056-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920067-Rightlung-extract Extraction other 920067-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920067-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920092-Rightlung-extract Extraction other 920092-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920092-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920093-Rightlung-extract Extraction other 920093-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920093-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920100-Rightlung-extract Extraction other 920100-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920100-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920109-Blood-extract Extraction other 920109-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920109-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920113-Rightlung-extract Extraction other 920113-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920113-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920115-Blood-extract Extraction other 920115-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920115-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920116-Rightlung-extract Extraction other 920116-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920116-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920128-Blood-extract Extraction other 920128-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920128-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920146-Rightlung-extract Extraction other 920146-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920146-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920157-Blood-extract Extraction other 920157-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920157-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920174-Rightlung-extract Extraction other 920174-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920174-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920175-Blood-extract Extraction other 920175-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920175-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920179-Blood-extract Extraction other 920179-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920179-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920186-Rightlung-extract Extraction other 920186-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920186-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920204-Blood-extract Extraction other 920204-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920204-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920208-Rightlung-extract Extraction other 920208-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920208-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920216-Blood-extract Extraction other 920216-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920216-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920223-Rightlung-extract Extraction other 920223-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920223-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920224-Rightlung-extract Extraction other 920224-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920224-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920229-Blood-extract Extraction other 920229-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920229-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920243-Rightlung-extract Extraction other 920243-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920243-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920250-Blood-extract Extraction other 920250-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920250-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920264-Blood-extract Extraction other 920264-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920264-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920265-Blood-extract Extraction other 920265-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920265-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920268-Rightlung-extract Extraction other 920268-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920268-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920274-Rightlung-extract Extraction other 920274-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920274-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920279-Rightlung-extract Extraction other 920279-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920279-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920280-Rightlung-extract Extraction other 920280-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920280-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920281-Blood-extract Extraction other 920281-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920281-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920300-Rightlung-extract Extraction other 920300-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920300-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920302-Blood-extract Extraction other 920302-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920302-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920303-Rightlung-extract Extraction other 920303-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920303-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920323-Blood-extract Extraction other 920323-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920323-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920327-Rightlung-extract Extraction other 920327-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920327-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920339-Blood-extract Extraction other 920339-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920339-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920346-Blood-extract Extraction other 920346-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920346-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920360-Blood-extract Extraction other 920360-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920360-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920368-Rightlung-extract Extraction other 920368-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920368-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920374-Rightlung-extract Extraction other 920374-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920374-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920375-Blood-extract Extraction other 920375-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920375-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920377-Blood-extract Extraction other 920377-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920377-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920383-Blood-extract Extraction other 920383-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920383-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920386-Blood-extract Extraction other 920386-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920386-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920393-Blood-extract Extraction other 920393-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920393-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920399-Rightlung-extract Extraction other 920399-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920399-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920404-Blood-extract Extraction other 920404-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920404-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920412-Rightlung-extract Extraction other 920412-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920412-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920414-Blood-extract Extraction other 920414-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920414-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920416-Rightlung-extract Extraction other 920416-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920416-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920417-Blood-extract Extraction other 920417-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920417-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920418-Blood-extract Extraction other 920418-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920418-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920421-Rightlung-extract Extraction other 920421-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920421-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920427-Blood-extract Extraction other 920427-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920427-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920430-Blood-extract Extraction other 920430-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920430-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920441-Blood-extract Extraction other 920441-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920441-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920455-Blood-extract Extraction other 920455-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920455-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920456-Blood-extract Extraction other 920456-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920456-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920460-Rightlung-extract Extraction other 920460-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920460-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920462-Rightlung-extract Extraction other 920462-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920462-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920478-Blood-extract Extraction other 920478-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920478-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920480-Blood-extract Extraction other 920480-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920480-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920484-Rightlung-extract Extraction other 920484-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920484-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920513-Blood-extract Extraction other 920513-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920513-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920524-Blood-extract Extraction other 920524-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920524-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920527-Blood-extract Extraction other 920527-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920527-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920531-Rightlung-extract Extraction other 920531-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920531-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920538-Blood-extract Extraction other 920538-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920538-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920540-Blood-extract Extraction other 920540-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920540-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920541-Blood-extract Extraction other 920541-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920541-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920548-Blood-extract Extraction other 920548-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920548-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920553-Rightlung-extract Extraction other 920553-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920553-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920563-Blood-extract Extraction other 920563-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920563-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920564-Blood-extract Extraction other 920564-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920564-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920570-Blood-extract Extraction other 920570-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920570-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920573-Blood-extract Extraction other 920573-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920573-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920587-Rightlung-extract Extraction other 920587-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920587-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920590-Rightlung-extract Extraction other 920590-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920590-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920602-Rightlung-extract Extraction other 920602-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920602-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920604-Rightlung-extract Extraction other 920604-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920604-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920605-Rightlung-extract Extraction other 920605-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920605-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920612-Blood-extract Extraction other 920612-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920612-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920616-Rightlung-extract Extraction other 920616-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920616-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920619-Blood-extract Extraction other 920619-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920619-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920621-Rightlung-extract Extraction other 920621-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920621-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920622-Blood-extract Extraction other 920622-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920622-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920630-Rightlung-extract Extraction other 920630-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920630-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920635-Blood-extract Extraction other 920635-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920635-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920642-Blood-extract Extraction other 920642-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920642-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920645-Rightlung-extract Extraction other 920645-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920645-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920657-Blood-extract Extraction other 920657-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920657-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920664-Rightlung-extract Extraction other 920664-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920664-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920673-Rightlung-extract Extraction other 920673-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920673-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920694-Blood-extract Extraction other 920694-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920694-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920696-Rightlung-extract Extraction other 920696-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920696-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920698-Blood-extract Extraction other 920698-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920698-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920700-Rightlung-extract Extraction other 920700-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920700-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920705-Rightlung-extract Extraction other 920705-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920705-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920711-Rightlung-extract Extraction other 920711-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920711-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920712-Rightlung-extract Extraction other 920712-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920712-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920728-Blood-extract Extraction other 920728-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920728-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920736-Rightlung-extract Extraction other 920736-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920736-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920738-Blood-extract Extraction other 920738-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920738-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920741-Rightlung-extract Extraction other 920741-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920741-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920751-Rightlung-extract Extraction other 920751-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920751-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920763-Rightlung-extract Extraction other 920763-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920763-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920768-Blood-extract Extraction other 920768-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920768-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920778-Blood-extract Extraction other 920778-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920778-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920788-Blood-extract Extraction other 920788-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920788-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920790-Blood-extract Extraction other 920790-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920790-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920791-Blood-extract Extraction other 920791-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920791-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920794-Rightlung-extract Extraction other 920794-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920794-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920796-Rightlung-extract Extraction other 920796-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920796-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920810-Blood-extract Extraction other 920810-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920810-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920818-Rightlung-extract Extraction other 920818-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920818-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920833-Blood-extract Extraction other 920833-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920833-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920843-Rightlung-extract Extraction other 920843-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920843-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920857-Rightlung-extract Extraction other 920857-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920857-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920861-Blood-extract Extraction other 920861-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920861-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920863-Blood-extract Extraction other 920863-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920863-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920880-Rightlung-extract Extraction other 920880-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920880-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920881-Blood-extract Extraction other 920881-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920881-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920885-Rightlung-extract Extraction other 920885-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920885-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920888-Rightlung-extract Extraction other 920888-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920888-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920893-Blood-extract Extraction other 920893-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920893-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920896-Blood-extract Extraction other 920896-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920896-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920899-Rightlung-extract Extraction other 920899-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920899-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920902-Rightlung-extract Extraction other 920902-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920902-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920903-Blood-extract Extraction other 920903-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920903-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920906-Rightlung-extract Extraction other 920906-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920906-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920907-Blood-extract Extraction other 920907-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920907-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920908-Rightlung-extract Extraction other 920908-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920908-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920922-Rightlung-extract Extraction other 920922-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920922-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920923-Blood-extract Extraction other 920923-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920923-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920933-Blood-extract Extraction other 920933-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920933-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920939-Blood-extract Extraction other 920939-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920939-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920941-Rightlung-extract Extraction other 920941-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920941-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920942-Rightlung-extract Extraction other 920942-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920942-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920947-Blood-extract Extraction other 920947-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920947-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920952-Rightlung-extract Extraction other 920952-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920952-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920959-Blood-extract Extraction other 920959-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920959-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920966-Blood-extract Extraction other 920966-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920966-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920981-Rightlung-extract Extraction other 920981-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920981-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920983-Rightlung-extract Extraction other 920983-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920983-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920984-Blood-extract Extraction other 920984-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920984-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920987-Blood-extract Extraction other 920987-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920987-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920988-Blood-extract Extraction other 920988-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920988-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
920993-Rightlung-extract Extraction other 920993-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920993-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921001-Rightlung-extract Extraction other 921001-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921001-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921007-Blood-extract Extraction other 921007-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921007-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921011-Blood-extract Extraction other 921011-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921011-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921013-Blood-extract Extraction other 921013-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921013-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921017-Rightlung-extract Extraction other 921017-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921017-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921020-Blood-extract Extraction other 921020-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921020-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921037-Rightlung-extract Extraction other 921037-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921037-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921047-Blood-extract Extraction other 921047-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921047-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921048-Blood-extract Extraction other 921048-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921048-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921057-Rightlung-extract Extraction other 921057-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921057-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921061-Blood-extract Extraction other 921061-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921061-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921062-Rightlung-extract Extraction other 921062-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921062-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921067-Rightlung-extract Extraction other 921067-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921067-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921081-Rightlung-extract Extraction other 921081-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921081-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921086-Rightlung-extract Extraction other 921086-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921086-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921089-Rightlung-extract Extraction other 921089-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921089-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921101-Blood-extract Extraction other 921101-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921101-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921109-Blood-extract Extraction other 921109-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921109-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921113-Rightlung-extract Extraction other 921113-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921113-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921114-Rightlung-extract Extraction other 921114-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921114-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921128-Rightlung-extract Extraction other 921128-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921128-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921132-Rightlung-extract Extraction other 921132-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921132-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921134-Rightlung-extract Extraction other 921134-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921134-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921138-Blood-extract Extraction other 921138-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921138-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921139-Rightlung-extract Extraction other 921139-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921139-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921140-Blood-extract Extraction other 921140-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921140-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921147-Blood-extract Extraction other 921147-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921147-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921152-Blood-extract Extraction other 921152-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921152-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921159-Rightlung-extract Extraction other 921159-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921159-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921166-Rightlung-extract Extraction other 921166-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921166-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921169-Blood-extract Extraction other 921169-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921169-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921173-Rightlung-extract Extraction other 921173-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921173-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921177-Rightlung-extract Extraction other 921177-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921177-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921183-Rightlung-extract Extraction other 921183-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921183-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921196-Blood-extract Extraction other 921196-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921196-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921200-Blood-extract Extraction other 921200-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921200-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921262-Rightlung-extract Extraction other 921262-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921262-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921276-Rightlung-extract Extraction other 921276-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921276-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921277-Blood-extract Extraction other 921277-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921277-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921278-Blood-extract Extraction other 921278-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921278-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921286-Rightlung-extract Extraction other 921286-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921286-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921294-Blood-extract Extraction other 921294-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921294-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921296-Rightlung-extract Extraction other 921296-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921296-Rightlung-lysate-LipidExtract-SPH 51803_R002_SPH_LU_ZP05_20120823.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921297-Rightlung-extract Extraction other 921297-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921297-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921304-Rightlung-extract Extraction other 921304-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921304-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921312-Blood-extract Extraction other 921312-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921312-Blood-Plasma-LipidExtract-SPH 51803_R023_SPH_PL_20121116.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921318-Rightlung-extract Extraction other 921318-Rightlung-lysate-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921318-Rightlung-lysate-LipidExtract-SPH 51803_R022_SPH_LU_20121115.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921319-Blood-extract Extraction other 921319-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921319-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv
921321-Blood-extract Extraction other 921321-Blood-Plasma-LipidExtract-SPH Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler AQUASIL C18 (5 um, 2.1 mm x 50 mm; Thermo Scientific) reverse phase Mass spectrometry negative AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 921321-Blood-Plasma-LipidExtract-SPH 51803_R001_SPH_PL_ZP05_20120824.wiff Data transformation Metabolite identification m_mtbls143_SPH_mass_spectrometry_v2_maf.tsv

Assay  2

Assay file name: a_mtbls143_CER_mass_spectrometry.txt
Technology: mass spectrometry
Platform: QTRAP 5500 (Applied Biosystems)

Instrumentation

Sample Name Protocol REF Post Extraction Derivatization Extract Name Protocol REF Chromatography Instrument Autosampler model Column model Column type Labeled Extract Name Label Protocol REF Scan polarity Scan m/z range Instrument Ion source Mass analyzer MS Assay Name Raw Spectral Data File Protocol REF Normalization Name Derived Spectral Data File Protocol REF Data Transformation Name Metabolite Assignment File
920025-Liver-extract Extraction other 920025-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920025-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920025-Rightlung-extract Extraction other 920025-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920025-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920031-Blood-extract Extraction other 920031-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920031-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920037-Liver-extract Extraction other 920037-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920037-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920037-Rightlung-extract Extraction other 920037-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920037-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920043-Liver-extract Extraction other 920043-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920043-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920043-Rightlung-extract Extraction other 920043-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920043-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920046-Blood-extract Extraction other 920046-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920046-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920050-Blood-extract Extraction other 920050-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920050-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920052-Blood-extract Extraction other 920052-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920052-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920056-Liver-extract Extraction other 920056-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920056-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920056-Rightlung-extract Extraction other 920056-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920056-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920067-Liver-extract Extraction other 920067-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920067-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920067-Rightlung-extract Extraction other 920067-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920067-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920092-Liver-extract Extraction other 920092-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920092-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920092-Rightlung-extract Extraction other 920092-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920092-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920093-Liver-extract Extraction other 920093-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920093-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920093-Rightlung-extract Extraction other 920093-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920093-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920100-Liver-extract Extraction other 920100-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920100-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920100-Rightlung-extract Extraction other 920100-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920100-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920109-Blood-extract Extraction other 920109-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920109-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920113-Liver-extract Extraction other 920113-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920113-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920113-Rightlung-extract Extraction other 920113-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920113-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920115-Blood-extract Extraction other 920115-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920115-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920116-Liver-extract Extraction other 920116-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920116-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920116-Rightlung-extract Extraction other 920116-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920116-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920128-Blood-extract Extraction other 920128-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920128-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920146-Liver-extract Extraction other 920146-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920146-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920146-Rightlung-extract Extraction other 920146-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920146-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920157-Blood-extract Extraction other 920157-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920157-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920174-Liver-extract Extraction other 920174-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920174-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920174-Rightlung-extract Extraction other 920174-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920174-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920175-Blood-extract Extraction other 920175-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920175-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920179-Blood-extract Extraction other 920179-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920179-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920186-Liver-extract Extraction other 920186-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920186-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920186-Rightlung-extract Extraction other 920186-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920186-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920204-Blood-extract Extraction other 920204-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920204-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920208-Liver-extract Extraction other 920208-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920208-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920208-Rightlung-extract Extraction other 920208-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920208-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920216-Blood-extract Extraction other 920216-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920216-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920223-Liver-extract Extraction other 920223-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920223-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920223-Rightlung-extract Extraction other 920223-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920223-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920224-Liver-extract Extraction other 920224-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920224-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920224-Rightlung-extract Extraction other 920224-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920224-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920229-Blood-extract Extraction other 920229-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920229-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920243-Liver-extract Extraction other 920243-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920243-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920243-Rightlung-extract Extraction other 920243-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920243-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920250-Blood-extract Extraction other 920250-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920250-Blood-Plasma-LipidExtract-CER 51803_R020_CER_PL_20121121.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920264-Blood-extract Extraction other 920264-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920264-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920265-Blood-extract Extraction other 920265-Blood-Plasma-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920265-Blood-Plasma-LipidExtract-CER 51803_R006_CER_PL_20120829.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920268-Liver-extract Extraction other 920268-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920268-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920268-Rightlung-extract Extraction other 920268-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920268-Rightlung-lysate-LipidExtract-CER 51803_R005_CER_LU_20120827.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920274-Liver-extract Extraction other 920274-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920274-Liver-lysate-LipidExtract-CER 51803_R018_CER_LI_20121123.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920274-Rightlung-extract Extraction other 920274-Rightlung-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920274-Rightlung-lysate-LipidExtract-CER 51803_R019_CER_LU_20121119.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920279-Liver-extract Extraction other 920279-Liver-lysate-LipidExtract-CER Chromatography Flux Rheos Allegro UHPLC pump CTC Analytics HTC PAL Autosampler ACQUITY UPLC BEH C18 (1.7 um, 2.1 mm x 50 mm; Waters) reverse phase Mass spectrometry positive AB SCIEX QTRAP 5500 MS:electrospray ionization CHMO:linear quadrupole ion trap mass-to-charge analyser 920279-Liver-lysate-LipidExtract-CER 51803_R008_CER_LI_20120831.wiff Data transformation Metabolite identification m_mtbls143_CER_mass_spectrometry_v2_maf.tsv
920279-Rightlung-extract Extraction other 920279-Rightlung-lysate-LipidExtract-CER