
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.4 20241031//EN" "JATS-archivearticle1-4-mathml3.dtd">
<article article-type="research-article" xml:lang="en" dtd-version="1.4"><front><journal-meta><journal-id journal-id-type="nlm-ta">Plant Methods</journal-id><journal-id journal-id-type="iso-abbrev">Plant Methods</journal-id><journal-id journal-id-type="pmc-domain-id">354</journal-id><journal-id journal-id-type="pmc-domain">plantmeth</journal-id><journal-id journal-id-type="nlm-id">101245798</journal-id><journal-title-group><journal-title>Plant Methods</journal-title></journal-title-group><issn pub-type="epub">1746-4811</issn><?publisher_abbrev csg?><publisher><publisher-name>BMC</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="pmcid">PMC8045372</article-id><article-id pub-id-type="pmcid-ver">PMC8045372.1</article-id><article-id pub-id-type="pmcaid">8045372</article-id><article-id pub-id-type="pmcaiid">8045372</article-id><article-id pub-id-type="pmid">33849587</article-id><article-id pub-id-type="doi">10.1186/s13007-021-00743-4</article-id><article-id pub-id-type="publisher-id">743</article-id><article-version article-version-type="pmc-version">1</article-version><article-categories><subj-group subj-group-type="heading"><subject>Methodology</subject></subj-group></article-categories><title-group><article-title>A device for the controlled cooling and freezing of excised plant specimens during magnetic resonance imaging</article-title></title-group><contrib-group><contrib contrib-type="author" equal-contrib="yes"><name name-style="western"><surname>Villouta</surname><given-names initials="C">Camilo</given-names></name><xref ref-type="aff" rid="Aff1">1</xref></contrib><contrib contrib-type="author" equal-contrib="yes"><name name-style="western"><surname>Cox</surname><given-names initials="BL">Benjamin L.</given-names></name><xref ref-type="aff" rid="Aff2">2</xref><xref ref-type="aff" rid="Aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Rauch</surname><given-names initials="B">Beth</given-names></name><xref ref-type="aff" rid="Aff4">4</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Workmaster</surname><given-names initials="BAA">Beth Ann A.</given-names></name><xref ref-type="aff" rid="Aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Eliceiri</surname><given-names initials="KW">Kevin W.</given-names></name><xref ref-type="aff" rid="Aff2">2</xref><xref ref-type="aff" rid="Aff3">3</xref><xref ref-type="aff" rid="Aff4">4</xref><xref ref-type="aff" rid="Aff5">5</xref></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0002-8921-5096</contrib-id><name name-style="western"><surname>Atucha</surname><given-names initials="A">Amaya</given-names></name><address><email>atucha@wisc.edu</email></address><xref ref-type="aff" rid="Aff1">1</xref></contrib><aff id="Aff1"><label>1</label><institution-wrap><institution-id institution-id-type="GRID">grid.14003.36</institution-id><institution-id institution-id-type="ISNI">0000 0001 2167 3675</institution-id><institution>Department of Horticulture, </institution><institution>University of Wisconsin-Madison, </institution></institution-wrap>1575 Linden Dr., Madison, WI 53706 USA </aff><aff id="Aff2"><label>2</label><institution-wrap><institution-id institution-id-type="GRID">grid.14003.36</institution-id><institution-id institution-id-type="ISNI">0000 0001 2167 3675</institution-id><institution>Medical Engineering Group, </institution><institution>Morgridge Institute for Research, </institution></institution-wrap>330 N Orchard St, Madison, WI 53706 USA </aff><aff id="Aff3"><label>3</label><institution-wrap><institution-id institution-id-type="GRID">grid.14003.36</institution-id><institution-id institution-id-type="ISNI">0000 0001 2167 3675</institution-id><institution>Laboratory for Optical and Computational Instrumentation (LOCI), </institution><institution>University of Wisconsin-Madison, </institution></institution-wrap>1675 Observatory Dr., Madison, WI 53706 USA </aff><aff id="Aff4"><label>4</label><institution-wrap><institution-id institution-id-type="GRID">grid.14003.36</institution-id><institution-id institution-id-type="ISNI">0000 0001 2167 3675</institution-id><institution>Department of Medical Physics, </institution><institution>University of Wisconsin-Madison, </institution></institution-wrap>1111 Highland Ave., Madison, WI 53705 USA </aff><aff id="Aff5"><label>5</label><institution-wrap><institution-id institution-id-type="GRID">grid.14003.36</institution-id><institution-id institution-id-type="ISNI">0000 0001 2167 3675</institution-id><institution>Department of Biomedical Engineering, </institution><institution>University of Wisconsin-Madison, </institution></institution-wrap>1415 Engineering Dr., Madison, WI 53706 USA </aff></contrib-group><pub-date pub-type="epub"><day>13</day><month>4</month><year>2021</year></pub-date><pub-date pub-type="collection"><year>2021</year></pub-date><volume>17</volume><issue-id pub-id-type="pmc-issue-id">372341</issue-id><elocation-id>41</elocation-id><history><date date-type="received"><day>19</day><month>11</month><year>2020</year></date><date date-type="accepted"><day>4</day><month>4</month><year>2021</year></date></history><pub-history><event event-type="pmc-release"><date><day>13</day><month>04</month><year>2021</year></date></event><event event-type="pmc-live"><date><day>14</day><month>04</month><year>2021</year></date></event><event event-type="pmc-last-change"><date iso-8601-date="2026-09-04 14:05:38.317"><day>04</day><month>09</month><year>2026</year></date></event></pub-history><permissions><copyright-statement>© The Author(s) 2021</copyright-statement><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/" specific-use="textmining" content-type="ccbylicense">https://creativecommons.org/licenses/by/4.0/</ali:license_ref><license-p><bold>Open Access</bold>This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">http://creativecommons.org/licenses/by/4.0/</ext-link>. The Creative Commons Public Domain Dedication waiver (<ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="https://creativecommons.org/publicdomain/zero/1.0/">http://creativecommons.org/publicdomain/zero/1.0/</ext-link>) applies to the data made available in this article, unless otherwise stated in a credit line to the data.</license-p></license></permissions><self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pmc-pdf" xlink:href="13007_2021_Article_743.pdf"><?pdf-name 13007_2021_Article_743.pdf?><?pdf-size 2067887?><?pdf-md5 1dbfc883c46916f6a8200fd3f339409d?><?pdf-image-server-status NEVER_LOAD?><?pdf-cloudpmc-urn urn:app:576e/8045372/1dbfc883c469/13007_2021_Article_743.pdf?></self-uri><abstract id="Abs1"><sec><title>Background</title><p id="Par1">Investigating plant mechanisms to tolerate freezing temperatures is critical to developing crops with superior cold hardiness. However, the lack of imaging methods that allow the visualization of freezing events in complex plant tissues remains a key limitation. Magnetic resonance imaging (MRI) has been successfully used to study many different plant models, including the study of in vivo changes during freezing. However, despite its benefits and past successes, the use of MRI in plant sciences remains low, likely due to limited access, high costs, and associated engineering challenges, such as keeping samples frozen for cold hardiness studies. To address this latter need, a novel device for keeping plant specimens at freezing temperatures during MRI is described.</p></sec><sec><title>Results</title><p id="Par2">The device consists of commercial and custom parts. All custom parts were 3D printed and made available as open source to increase accessibility to research groups who wish to reproduce or iterate on this work. Calibration tests documented that, upon temperature equilibration for a given experimental temperature, conditions between the circulating coolant bath and inside the device seated within the bore of the magnet varied by less than 0.1 °C. The device was tested on plant material by imaging buds from <italic toggle="yes">Vaccinium macrocarpon</italic> in a small animal MRI system, at four temperatures, 20 °C, − 7 °C, − 14 °C, and −  21 °C. Results were compared to those obtained by independent controlled freezing test (CFT) evaluations. Non-damaging freezing events in inner bud structures were detected from the imaging data collected using this device, phenomena that are undetectable using CFT.</p></sec><sec><title>Conclusions</title><p id="Par3">The use of this novel cooling and freezing device in conjunction with MRI facilitated the detection of freezing events in intact plant tissues through the observation of the presence and absence of water in liquid state. The device represents an important addition to plant imaging tools currently available to researchers. Furthermore, its open-source and customizable design ensures that it will be accessible to a wide range of researchers and applications.</p></sec></abstract><kwd-group xml:lang="en"><title>Keywords</title><kwd>MRI</kwd><kwd>3D printing</kwd><kwd>Dormant bud</kwd><kwd>Freezing resistance</kwd><kwd>Plant cold hardiness</kwd></kwd-group><custom-meta-group><custom-meta><meta-name>pmc-status-qastatus</meta-name><meta-value>0</meta-value></custom-meta><custom-meta><meta-name>pmc-status-live</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-status-embargo</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-status-released</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-open-access</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-olf</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-manuscript</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-legally-suppressed</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-has-pdf</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-has-supplement</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-pdf-only</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-suppress-copyright</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-is-real-version</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-is-scanned-article</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-preprint</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-in-epmc</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-license-ref</meta-name><meta-value>CC BY</meta-value></custom-meta><custom-meta><meta-name>issue-copyright-statement</meta-name><meta-value>© The Author(s) 2021</meta-value></custom-meta></custom-meta-group></article-meta></front><body><sec id="Sec1"><title>Introduction</title><p id="Par8">Woody plants' adaptations to withstand freezing temperatures are key for their survival in environments with extreme winter temperatures, as well as, in the case of agricultural crops, for the attainment of consistent yields under the threat of climate change [<xref ref-type="bibr" rid="CR1">1</xref>–<xref ref-type="bibr" rid="CR4">4</xref>]. A better understanding of the freezing survival mechanisms utilized by plant tissues is critical to identifying genetic variation in freezing tolerance, and thus the development of plant material with enhanced cold hardiness.</p><p id="Par9">Woody plant buds are particularly vulnerable to damage by extreme freezing temperatures [<xref ref-type="bibr" rid="CR5">5</xref>]. Although several studies in multiple woody species have focused on freezing patterns and freezing tolerance of buds [<xref ref-type="bibr" rid="CR6">6</xref>–<xref ref-type="bibr" rid="CR8">8</xref>], the technical difficulties of visualizing freezing events of individual structures within woody buds remain a major limitation to this line of research [<xref ref-type="bibr" rid="CR7">7</xref>].</p><p id="Par10">Currently, magnetic resonance imaging (MRI) is the only tool with which the non-destructive study of the propagation and distribution of ice formation in complex plant organs at different experimental temperatures is possible [<xref ref-type="bibr" rid="CR9">9</xref>]. The use of this technique is based on the drastic change in signal intensity detected by MRI when water changes from liquid state to solid state (ice). It is possible to analyze MRI images by measuring mean gray values (MGV), where bright areas represent liquid water, and dark areas represent areas of low proton density, as well as water that has just frozen [<xref ref-type="bibr" rid="CR10">10</xref>]. Insight into the freezing mechanisms used by plant tissues can be determined by the acquisition of images at a series of different temperatures [<xref ref-type="bibr" rid="CR7">7</xref>], allowing researchers to infer where and when ice is being formed. This approach results in a robust technique for the study of plant cold hardiness [<xref ref-type="bibr" rid="CR11">11</xref>].</p><p id="Par11">MRI has been successfully used to study many different plant models, including the study of in vivo changes during freezing for several species [<xref ref-type="bibr" rid="CR6">6</xref>–<xref ref-type="bibr" rid="CR8">8</xref>, <xref ref-type="bibr" rid="CR11">11</xref>, <xref ref-type="bibr" rid="CR12">12</xref>], physiological processes [<xref ref-type="bibr" rid="CR13">13</xref>], and dormancy induction in woody plants, including their adaptation to environmental conditions [<xref ref-type="bibr" rid="CR14">14</xref>, <xref ref-type="bibr" rid="CR15">15</xref>]. However, despite its benefits and past successes, the use of MRI in plant sciences remains low, likely due to limited access, high costs, and associated engineering challenges. Engineering challenges are of particular concern when attempting the study of plant buds with MRI at freezing temperatures, given the need to keep plant samples at consistent freezing temperatures within the MRI equipment for many hours. Addressing these challenges, the objective of this report is to describe the design, fabrication, and testing of a low-cost MRI-compatible sample holder and cooling device that enables the controlled freezing of plant specimens while samples are scanned in an MRI device.</p></sec><sec id="Sec2"><title>Results and discussion</title><sec id="Sec3"><title>Device design</title><p id="Par12">The overall assembly and individual components of the cooling device were designed using SolidWorks (Dassault Systemes, Velizy-Villacoublay, France), a computer-aided design (CAD) software package. The resulting device was a custom assembly to hold the samples and sit within the bore of the magnet. The device was part of a cooling circuit that includes a temperature-controlled coolant pool and pump located in the control room of the MR system, as well as tubing and fittings to connect the two sides of the circuit (Fig. <xref rid="Fig1" ref-type="fig">1</xref>). The assembled device (Fig. <xref rid="Fig1" ref-type="fig">1</xref>b) consisted of a coolant chamber surrounding a sample chamber that are independent of one another. The independence of the inner sample chamber is for the use of an inert perfluorocarbon solution typically used to enhance MR image clarity (Fig. <xref rid="Fig1" ref-type="fig">1</xref>b). Cooled coolant was pumped through the coolant chamber and around the sample chamber, effecting heat transfer from the plant specimen within the sample chamber (Fig. <xref rid="Fig1" ref-type="fig">1</xref>a). The individual components of the device included three custom 3D printed parts and several commercially available components (Table <xref rid="Tab2" ref-type="table">2</xref>). Three interchangeable sample holders were designed and built (Fig. <xref rid="Fig2" ref-type="fig">2</xref>j) for flexibility with a range of plant specimens.<fig id="Fig1" position="float" orientation="portrait"><label>Fig. 1</label><caption><p>Cooling circuit and device design. Schematic showing the cooling circuit detailing locations of the coolant pool and pump in the control room (<bold>a</bold>) and the cooling device within the MRI (<bold>b</bold>). CAD diagram of assembled cooling device (<bold>b</bold>) highlighting the sample chamber (pink). The remaining interior volume is comprised of the surrounding coolant chamber through which chilled ethylene glycol is pumped. Scale bar is approximately 2 cm</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO1" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig1_HTML.jpg"><?image-name 13007_2021_743_Fig1_HTML.jpg?><?image-size 35328?><?image-md5 23502f0d802d4bda620405c06e01d0e3?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 488?><?image-original-width 1957?><?image-scaled-height 195?><?image-scaled-width 782?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/23502f0d802d/13007_2021_743_Fig1_HTML.jpg?><?thumb-name 13007_2021_743_Fig1_HTML.gif?><?thumb-size 8597?><?thumb-md5 97e87780b80e4d0de8e630f7577d1b8c?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 50?><?thumb-scaled-width 200?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/97e87780b80e/13007_2021_743_Fig1_HTML.gif?></graphic></fig><fig id="Fig2" position="float" orientation="portrait"><label>Fig. 2</label><caption><p>Components of the cooling device and experimental cooling circuit. The fabricated cooling device (<bold>a</bold>–<bold>c</bold>), including the individual device parts (<bold>a</bold>), view of cap end of the assembled device (<bold>b</bold>), and view of coolant inlet/outlet end of the assembled device (<bold>c</bold>). Neoprene-insulated Tygon® tubing, for conducting the chilled ethylene glycol (<bold>d</bold>), is further wrapped in an additional layer of polyethylene pipe insulation (<bold>e</bold>). A peristaltic pump (<bold>f</bold>) delivers the chilled ethylene glycol to the cooling device while situated in the MRI unit (<bold>g</bold>, <bold>h</bold>) from the circulating bath (coolant pool) (<bold>i</bold>) via the insulated tubing. Chilled coolant flows through the sample chamber, containing the sample holder comprised of several individual sample tubes. Sample holders were made to hold tubes of three different sizes (<bold>j</bold>), to accommodate a range of excised plant specimens</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO2" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig2_HTML.jpg"><?image-name 13007_2021_743_Fig2_HTML.jpg?><?image-size 124718?><?image-md5 250408f585f4a7290c1ae0bb537adc61?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1352?><?image-original-width 1652?><?image-scaled-height 540?><?image-scaled-width 660?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/250408f585f4/13007_2021_743_Fig2_HTML.jpg?><?thumb-name 13007_2021_743_Fig2_HTML.gif?><?thumb-size 19158?><?thumb-md5 89434dcdae79e9f836c82521bca21b00?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 82?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/89434dcdae79/13007_2021_743_Fig2_HTML.gif?></graphic></fig></p></sec><sec id="Sec4"><title>Device fabrication</title><p id="Par13">There were three custom components of the cooling device (Fig. <xref rid="Fig2" ref-type="fig">2</xref>), which were 3D printed using a Viper Si2 Stereolithography System (3D Systems, Rock Hill, SC, USA) using Accura60, a proprietary photopolymer resin (3D Systems). This resin has chemical similarities to UV-cure epoxy, requiring the use of UV light for solidification. This material, when solid, has similar properties to acrylic. The main body of the device was printed upright with the larger end facing down and without supports on the inside of the coolant chamber (to avoid supports being trapped inside). The larger holes connected to the coolant chamber (Fig. <xref rid="Fig2" ref-type="fig">2</xref>a, left side) were tapped to accommodate the fittings used to pump the coolant. The smaller holes at the other end of the coolant chamber (Fig. <xref rid="Fig2" ref-type="fig">2</xref>a, right side) were tapped for bolts to seal the device cap. A 2 mm diameter conduit was made from the larger end and until the base of the inner chamber to place a temperature probe. Lastly, the smallest custom component, the cap, was used to seal the sample chamber using an O-ring. A center hole in the cap can be sealed last, after assembly, and is used to top off the fluid in the sample chamber. All materials, tubing connectors, and bolts were selected to be MRI-compatible (non-ferromagnetic and low magnetic susceptibility), and to not interact with the circulating coolant (Fig. <xref rid="Fig2" ref-type="fig">2</xref>).</p></sec><sec id="Sec5"><title>Novel design features</title><p id="Par14">The cooling device has several innovative design features that facilitated the necessary cooling of samples and the acquisition of quality images (Fig. <xref rid="Fig3" ref-type="fig">3</xref>). The resulting device had two chambers, an inner sample chamber surrounded by a coolant chamber through which chilled ethylene glycol flowed (Fig. <xref rid="Fig3" ref-type="fig">3</xref>). The coolant chamber was designed to envelop the sample chamber, facilitating cooling through convective heat loss from the samples as coolant flowed around them, as well as conductive heat loss through the barrier between the two chambers. Orientation markers were included around the sample chamber for longitudinal and axial sample positioning (Fig. <xref rid="Fig3" ref-type="fig">3</xref>, Bottom). The fluid inlet and outlet were tapped to accommodate commercial tubing connectors (Table <xref rid="Tab2" ref-type="table">2</xref>).<fig id="Fig3" position="float" orientation="portrait"><label>Fig. 3</label><caption><p>CAD drawings of cooling device for MRI imaging of frozen excised plant specimens. Longitudinal cutaway views at orthogonal planes; one view showing locations of material fins in the imaging plane (top image, blue line); and one view showing the inlet and outlet ports for the circulating coolant (bottom image, red line). Both longitudinal views show the temperature probe conduit for sample chamber temperature monitoring. Also shown is an axial cutaway view (green line). Orientation markers are indicated in each cutaway view. Bars equal 2 cm</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO3" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig3_HTML.jpg"><?image-name 13007_2021_743_Fig3_HTML.jpg?><?image-size 133469?><?image-md5 fd6a08c8fa993fe4c1f07e3ebeaa73a8?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1264?><?image-original-width 1960?><?image-scaled-height 506?><?image-scaled-width 784?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/fd6a08c8fa99/13007_2021_743_Fig3_HTML.jpg?><?thumb-name 13007_2021_743_Fig3_HTML.gif?><?thumb-size 16554?><?thumb-md5 64a70d668e19cf8c32fda06ad9d2d37d?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 80?><?thumb-scaled-width 124?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/64a70d668e19/13007_2021_743_Fig3_HTML.gif?></graphic></fig></p><p id="Par15">Through several prototype iterations, we detected the need to include fins of material on either side of the sample chamber in the imaging plane (Fig. <xref rid="Fig3" ref-type="fig">3</xref>, Top) to remove imaging artifacts created by the flow of the circulating ethylene glycol, which obscured the view of the sample chamber (Fig. <xref rid="Fig4" ref-type="fig">4</xref>a). The inclusion of the fins directed the ethylene glycol outside of the imaging plane, allowing the clear imaging of the <italic toggle="yes">V. macrocarpon</italic> buds (Fig. <xref rid="Fig4" ref-type="fig">4</xref>b).<fig id="Fig4" position="float" orientation="portrait"><label>Fig. 4</label><caption><p>Imaging artifacts created by the flow of ethylene glycol in the coolant chamber. Imaging artifacts (within highlighted box) (<bold>a</bold>) were eliminated from the sample chamber view by modifying the device to include material fins to divert the coolant flow from the imaged volume along the longitudinal axis of the device. As a result, clear images of <italic toggle="yes">V. macrocarpon</italic> (<bold>b</bold>) bud samples were obtained. Scale bar equals 5 mm</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO4" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig4_HTML.jpg"><?image-name 13007_2021_743_Fig4_HTML.jpg?><?image-size 100701?><?image-md5 efe1cae21f72c5367756154badfabb1d?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1045?><?image-original-width 1594?><?image-scaled-height 523?><?image-scaled-width 797?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/efe1cae21f72/13007_2021_743_Fig4_HTML.jpg?><?thumb-name 13007_2021_743_Fig4_HTML.gif?><?thumb-size 14098?><?thumb-md5 6324722ea6fb649f05c2f5cf2eed2560?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 80?><?thumb-scaled-width 122?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/6324722ea6fb/13007_2021_743_Fig4_HTML.gif?></graphic></fig></p></sec><sec id="Sec6"><title>Cooling calibration and frost control</title><p id="Par16">A calibration test was performed to determine the variations in temperature between the set temperature on the circulating bath and the target temperature measured inside the device (Table <xref rid="Tab1" ref-type="table">1</xref>). The calibration was necessary due to the lack of access to a MRI-compatible temperature probe able to monitor the freezing temperatures in real time. For the calibration, the experimental freezing rate of 3 °C/h was used, and once a test temperature was reached, it was held for 20 min to ensure equilibration. Once equilibrium was reached for a given test temperature, conditions in the bath and the device varied by less than 0.1 °C. As expected, temperatures in the cold bath were consistently lower than those measured inside the device, due to heat gain through the tubing that ran between the bath and the cooling device, despite two layers of insulation.<table-wrap id="Tab1" position="float" orientation="portrait"><label>Table 1</label><caption><p>Calibration of circulating coolant bath set temperatures to device experimental treatment temperatures</p></caption><table frame="hsides" rules="groups"><thead><tr><th align="left" colspan="1" rowspan="1">Cold bath set temperature (°C)</th><th align="left" colspan="1" rowspan="1">Corresponding device temperature (°C)</th></tr></thead><tbody><tr><td align="left" colspan="1" rowspan="1">− 7.9</td><td char="±" align="char" colspan="1" rowspan="1">− 7.0 ± 0.1</td></tr><tr><td align="left" colspan="1" rowspan="1">− 16.0</td><td char="±" align="char" colspan="1" rowspan="1">− 14.0 ± 0.1</td></tr><tr><td align="left" colspan="1" rowspan="1">− 24.2</td><td char="±" align="char" colspan="1" rowspan="1">− 21.0 ± 0.1</td></tr></tbody></table><table-wrap-foot><p>Determination of correspondence of temperatures between the circulating coolant bath and the effective temperature experience at the device installed inside the MRI equipment. Temperature variations are attributed to coolant (ethylene glycol) heat gain during circulation through the tubing system</p></table-wrap-foot></table-wrap></p><p id="Par17">Frost control around the device was an important consideration during the experimental procedure, as excess moisture could damage the MRI system or the supporting electronics. This problem was compounded by the extended acquisition times (52 min) required for the MRI, as well as the slow freezing rates, which resulted in the system running for several hours at a time. The foam insulation covering the entire length of the tubing system limited frost buildup, as well as reduced heat transfer to the flowing coolant. A 3.5 mm thickness neoprene sleeve (Seattle Fabrics, United States) was also placed around the cooling device during scans to protect the coil and MRI components.</p></sec><sec id="Sec7"><title><italic toggle="yes">Vaccinium macrocarpon</italic> bud freezing with our novel device</title><p id="Par18">Images of <italic toggle="yes">V. macrocarpon</italic> buds from the MRI scans did not have sufficient quality to identify individual tissues within the bud, as compared to a dissected sample (Fig. <xref rid="Fig5" ref-type="fig">5</xref>a to e), but this was expected due to the small bud size (1–2 mm diameter). However, the images had sufficient resolution to distinguish regions of interest (ROI) within the bud (i.e., outer bud, inner bud, and stem section) (Fig. <xref rid="Fig5" ref-type="fig">5</xref>f). Only buds yielding a complete longitudinal slice were selected (n = 14) for image analysis. Images were analyzed by determining the mean gray values (MGV) for the three ROIs: outer bud, inner bud, and stem (Fig. <xref rid="Fig5" ref-type="fig">5</xref>f) for each bud. MGV is a useful indicator of water and its physical state in these samples [<xref ref-type="bibr" rid="CR9">9</xref>], where bright areas represent liquid water and dark areas represent frozen water. Variations in MGV in the ROI were observed over the range of experimental temperatures (Fig. <xref rid="Fig5" ref-type="fig">5</xref>g). The increase in average MGV as the samples cooled to − 7 °C is the result of an enhancement of signal detection as the sample and coil temperatures decrease [<xref ref-type="bibr" rid="CR10">10</xref>] and is also an effect from a change in the Boltzmann distribution [<xref ref-type="bibr" rid="CR16">16</xref>]. A rapid decrease in signal intensity from − 14 °C to − 21 °C is surmised to correspond with the temperature range over which liquid water in these regions of the bud tissue gradually freeze.<fig id="Fig5" position="float" orientation="portrait"><label>Fig. 5</label><caption><p>Example of a fresh <italic toggle="yes">V. macrocarpon</italic> bud in longitudinal section, obtained MRI images at evaluated temperatures, and plots of MGVs by defined ROIs. Fresh longitudinal section of <italic toggle="yes">V. macrocarpon</italic> bud indicating main anatomical structures (<bold>a</bold>) (B = bark; BA = bud axis; IB = inner bud (apical meristem and flower primordia); P = pith; S = bud scales; VT = vascular tissue). Longitudinal MR images obtained at 20, − 7, − 14, and − 21 °C (<bold>b</bold>–<bold>e</bold>, respectively) from specimens collected in November 2018 (n = 14). Images are close-ups of averages of 23 scans with a field of view of 30 × 30 mm with 512 × 512 pixels. Higher MGV (brighter) areas of images indicate unfrozen tissues. Evaluated ROIs of <italic toggle="yes">V. macrocarpon</italic> bud (<bold>f</bold>): blue = outer bud; red = inner bud; green = stem. Plot of changes in MGV for each ROI by temperature exposure (G), originally published in Villouta et al. [<xref ref-type="bibr" rid="CR19">19</xref>]. Vertical error bars represent the standard error of the mean. Scale bar in A, B, and F equals 1 mm</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO5" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig5_HTML.jpg"><?image-name 13007_2021_743_Fig5_HTML.jpg?><?image-size 97163?><?image-md5 1d5a7e9911c8109c6ec7054595f924a0?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1122?><?image-original-width 1960?><?image-scaled-height 449?><?image-scaled-width 784?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/1d5a7e9911c8/13007_2021_743_Fig5_HTML.jpg?><?thumb-name 13007_2021_743_Fig5_HTML.gif?><?thumb-size 16316?><?thumb-md5 42aaa0106c747e737225fe3f4ed2f028?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 80?><?thumb-scaled-width 139?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/42aaa0106c74/13007_2021_743_Fig5_HTML.gif?></graphic></fig></p></sec><sec id="Sec8"><title>Comparison to controlled freezing test (CFT) data</title><p id="Par19">Near-simultaneously to the MRI acquisitions, samples were evaluated using a controlled freezing test (CFT), a conventional technique for cold hardiness assessments [<xref ref-type="bibr" rid="CR17">17</xref>]. CFT involves placing the samples in a programmable freezer, where the air temperature decreases at a controlled rate. Following this, frozen samples are removed from the programmable freezer at pre-determined tested temperatures and placed on ice. This step allows samples to thaw at a slow rate for tissue recovery and damage expression to occur. Damage is scored through visual quantification of tissue browning and water-soaking appearance.</p><p id="Par20">Freezing events detected from the MRI acquisitions were not detectable in the CFT observations as damaging. In the MRI, the outer bud MGV decreased to values near 0 at − 14 °C and − 21 °C (Fig. <xref rid="Fig5" ref-type="fig">5</xref>g), and this reduction in the relative content of liquid water was indicative of a freezing event [<xref ref-type="bibr" rid="CR6">6</xref>]. However, in the CFT, the same ROI did not show damage (expressed as tissue browning) until temperatures reached below − 24 °C (Fig. <xref rid="Fig6" ref-type="fig">6</xref>). Similarly, a reduction in the inner bud MGV was observed at − 14 °C, with a larger decrease at − 21 °C (Fig. <xref rid="Fig5" ref-type="fig">5</xref>g). However, in the CFT, damage was noted only when temperatures were below − 24 °C (Fig. <xref rid="Fig6" ref-type="fig">6</xref>). Our results show that the use of the cooling device during MRI facilitates the detection of non-damaging freezing events in the inner structures of buds, which are not detected by the traditional CFT technique.<fig id="Fig6" position="float" orientation="portrait"><label>Fig. 6</label><caption><p>CFT-incurred damage in <italic toggle="yes">V. macrocarpon</italic> terminal buds. Plots of the mean relative damage to each of the three bud areas in terminal buds of <italic toggle="yes">V. macrocarpon</italic> by the degree of exposure to sequential temperatures (°C) in controlled freezing tests (CFTs). Buds were sampled November 1 and 15, 2018 from a commercial farm near Nekoosa, WI. Relative damage was scored using a discrete scale with four levels of severity, where 0 represents no damage and 3 complete damage (n = 15). Vertical bars represent the standard error of the mean</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO6" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig6_HTML.jpg"><?image-name 13007_2021_743_Fig6_HTML.jpg?><?image-size 141006?><?image-md5 07a03b87d4c333df036711e8673c14e5?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 2184?><?image-original-width 1593?><?image-scaled-height 1091?><?image-scaled-width 796?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/07a03b87d4c3/13007_2021_743_Fig6_HTML.jpg?><?thumb-name 13007_2021_743_Fig6_HTML.gif?><?thumb-size 12932?><?thumb-md5 a3ba4dbbda77886b62b95ef6a43335b2?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 137?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/a3ba4dbbda77/13007_2021_743_Fig6_HTML.gif?></graphic></fig></p></sec></sec><sec id="Sec9"><title>Discussion</title><p id="Par21">This device and accompanying system has the potential to reach temperatures lower than reported in this study. However, several factors must be considered in advance, such as the freezing capability of the coolant bath, the effectiveness of the tubing system insulation, and the viscosity of the coolant at freezing temperatures. Reaching lower temperatures could expand this device's use to the study of plant species with buds or other tissues with reported survival at temperatures lower than − 21 °C [<xref ref-type="bibr" rid="CR18">18</xref>].</p><p id="Par22">While this device represents an important development in plant imaging tools, there are several potential design and procedure improvements for future iterations. The incorporation of a MR-compatible temperature probe would permit real-time temperature measurements of the samples during image acquisition, rather than the reliance on the calibration data obtained pre-experiment with an incompatible temperature probe. Due to the toxicity of ethylene glycol, an alternative coolant, such as propylene glycol, could be considered to improve safety and ease of use. Since a key aspect of this device is the interchangeability of the three sample holders, additional holder designs could be made to expand the sizes of excised plant specimens tested. As well, improvements to the control of sample orientation within the tubes of the sample holder would increase the likelihood of capturing image slices along the longitudinal axes of the samples. Lastly, a custom plug to simultaneously cap all of the tubes of the sample holder would streamline preparation.</p></sec><sec id="Sec10"><title>Conclusion</title><p id="Par23">This device, in conjunction with the circulating cooling system, allows researchers to successfully freeze samples in a stepwise way while performing MRI acquisitions. The low-cost of 3D printing for the main device components will lower the technical barrier to using MRI technology to visualize the freezing patterns of complex plant organs. Widespread use of this technique could further our knowledge of the mechanisms of freezing stress resistance in plants. All necessary design files for this device are made available as open-source at: <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="https://morgridge.org/designs">https://morgridge.org/designs</ext-link>. It is the hope of the authors that other research groups will build this device and iterate upon it.</p></sec><sec id="Sec11"><title>Methods</title><sec id="Sec12"><title>Experimental setup</title><p id="Par24">This experimental setup is comprised of the cooling device and numerous pieces of supporting hardware (Fig. <xref rid="Fig2" ref-type="fig">2</xref>). Images of the fabricated device can be seen in Fig. <xref rid="Fig2" ref-type="fig">2</xref>a–c, including each component and two separate views of the assembled device. A coolant system pumps chilled coolant (ethylene glycol) from a circulating bath into the coolant chamber of the device surrounding the sample chamber, providing localized cooling. Clear high chemical resistance Tygon® R-3603 laboratory tubing (0.25 inch I.D., 0.378 inch O.D.) (Saint-Gobain, Malvern, PA) (Fig. <xref rid="Fig2" ref-type="fig">2</xref>d–e) is insulated and transports ethylene glycol (1:1 diluted) (Prestone, Lake Forest, IL) from a refrigerated circulating bath (Model AD07R-40, Polyscience, Niles, IL) via a Masterflex L/S Variable-Speed Console peristaltic pump (Cole-Palmer, Vernon Hills, IL) (Fig. <xref rid="Fig2" ref-type="fig">2</xref>f–i). Each line of the Tygon® tubing was wrapped with 1.5 mm thick single-side adhesive neoprene sheeting (The Felt Store, Ontario, Canada) and jointly covered by a 1.9 cm thick pre-slit polyethylene pipe insulation (Tundra, United States). A 3.5 mm thick neoprene (Seattle Fabrics, United States) sleeve was custom-made to jacket the device to inhibit frost formation and contribute insulation.</p></sec><sec id="Sec13"><title>Sample preparation</title><p id="Par25"><italic toggle="yes">Vaccinium macrocarpon</italic> buds were collected from a commercial cranberry farm in Nekoosa (44° 16′46.9" N, 89° 55′00.4" W), WI, and sampled on November 7, 2018. Buds were collected and transported in sealed plastic bags on ice. Samples were processed within 24 h of field collection for MRI acquisition. <italic toggle="yes">V. macrocarpon</italic> uprights were sorted by terminal bud size, selecting for medium-size buds (1–2 mm diameter).</p><p id="Par26"><italic toggle="yes">Vaccinium macrocarpon</italic> terminal buds were excised leaving 5 mm of stem attached with no leaves (Fig. <xref rid="Fig7" ref-type="fig">7</xref>a). Cut ends of the stems were sealed with a layer of high vacuum grease (Dow Corning, Midland, MI) to avoid dehydration. Buds were lined up in the tubes of the smallest sample holder (Fig. <xref rid="Fig7" ref-type="fig">7</xref>b), separated by paper stoppers between buds (Fig. <xref rid="Fig7" ref-type="fig">7</xref>c). 28 buds were placed inside the sample holder. Once buds were positioned inside the sample holder, cylinder ends were capped with silicone plugs. Next, the sample holder was placed inside the sample chamber of the cooling device (Fig. <xref rid="Fig7" ref-type="fig">7</xref>c) and an inert perfluorocarbon (to enhance the MR image clarity) (Fluorinert, 3 M, St. Louis, MN) was poured into the interstitial space prior to sealing the device.<fig id="Fig7" position="float" orientation="portrait"><label>Fig. 7</label><caption><p>Loading of <italic toggle="yes">V. macrocarpon</italic> bud specimens into cooling device sample holders. <italic toggle="yes">V. macrocarpon</italic> samples prepared for controlled freezing MRI run, including untrimmed and trimmed buds (<bold>a</bold>), trimmed buds being loaded into tubes of the sample holder (<bold>b</bold>), and a loaded sample holder, with buds separated by paper stoppers (<bold>c</bold>). Bars equal 1 cm</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" id="MO7" position="float" orientation="portrait" xlink:href="13007_2021_743_Fig7_HTML.jpg"><?image-name 13007_2021_743_Fig7_HTML.jpg?><?image-size 56562?><?image-md5 24c1cc6d3608141ad215debbff40beba?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 778?><?image-original-width 1960?><?image-scaled-height 311?><?image-scaled-width 784?><?image-cloudpmc-urn urn:cdn:blobs/576e/8045372/24c1cc6d3608/13007_2021_743_Fig7_HTML.jpg?><?thumb-name 13007_2021_743_Fig7_HTML.gif?><?thumb-size 17888?><?thumb-md5 c47d3dc3caafba1092f7623ff321a49a?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 79?><?thumb-scaled-width 200?><?thumb-cloudpmc-urn urn:cdn:blobs/576e/8045372/c47d3dc3caaf/13007_2021_743_Fig7_HTML.gif?></graphic></fig></p></sec><sec id="Sec14"><title>Controlled freezing test</title><p id="Par27">The CFT procedure was based on that of Villouta et al. [<xref ref-type="bibr" rid="CR19">19</xref>], and was performed on two sampling dates, November 1 and 15, 2018. Both CFT tests were performed in a programmable freezer chamber (Tenney Model T2C, Thermal Product Solutions, New Columbia, PA, USA). Additional temperature monitoring was done with two copper-constantan (Type T) thermocouples (22 AWG) located inside the freezing chamber.</p><p id="Par28">Uprights of at least 10 cm long and with a dormant tight bud were selected and rinsed in tap water. After trimming to 8 cm long, uprights were blotted dry with a paper towel. Uprights were grouped in bunches of five, and at their cut end, the set was wrapped with moist paper towel. Sets were placed in 50 ml plastic centrifuge tubes with plastic caps. Three replicate tubes were used at each test temperature. For the temperature lowering scheme, the first step was to reach − 1 °C and maintain it for one hour to allow thermal equilibrium. On following steps, decreasing rates were 1, 2, and 4 °C/h for the intervals − 1 to − 6 °C, − 6 to − 12 °C and − 12 °C to the minimum evaluated temperature, respectively. For ice nucleation induction, the racks containing the sample tubes were firmly shook during the temperature equilibration at − 1 °C.</p><p id="Par29">Sets of three tubes were removed from the freezing chamber at eight test temperatures, ranging between 0 and − 50 °C. The removed tubes were placed in ice and darkness for 12 h followed by a period of 72 h at 4 °C in darkness to allow recovery of any potential tissue injury. Afterwards, tubes were held at room temperature for 24 h in low light conditions to allow damage symptom expression in bud structures.</p></sec><sec id="Sec15"><title>Bud damage evaluation</title><p id="Par30">Bud damage evaluation was performed as described in Villouta et al. [<xref ref-type="bibr" rid="CR19">19</xref>], using an Olympus SZX12 dissection microscope with a 1× objective (Olympus Optical Company, Tokyo, Japan) connected to a Canon EOS Rebel T6i digital camera (Canon U.S.A., Inc., Melville, NY, USA). For the evaluation of browning distribution and severity, buds were sectioned longitudinally with a razorblade and immediately assessed. The evaluated bud regions were determined based on the structures determined by Villouta et al. [<xref ref-type="bibr" rid="CR19">19</xref>] where bud scales represent the outer bud, the shoot apical meristem (SAM), flower primordia, and bud axis comprised the inner bud, and the attached stem section represents the stem (Fig. <xref rid="Fig5" ref-type="fig">5</xref>f). A discrete scale comprising four levels of damage, ranging from 0 (no damage) to 3 (complete damage) in terms of the severity of oxidative browning and water-appearance, was used.</p></sec><sec id="Sec16"><title>Image acquisition</title><p id="Par31">MRI was performed using a Varian 4.7-T small animal imaging system, and an Agilent/Varian <sup>1</sup>H 200 MHz quadrature birdcage volume coil (Agilent Technologies, Palo Alto, CA, USA). The cooling device was inserted inside the coil for scanning. Images were acquired using a spin echo multi-slice (SEMS) pulse sequence. Acquisition parameters were set as follows: TR 306.4 ms, TE 21.5 ms, N 20, 512 × 512 matrix. Field of view was 30 × 30 mm with 10, 1-mm thick slices scanned 23 times. The MRI run consisted of equilibration of the sample chamber for 20 min at each treatment temperature and a hold for the duration of each image acquisition. Total acquisition time per test temperature was 52 min. After the 20 °C image acquisition, the chamber temperature was ramped to − 1 °C at a rate of 10 °C/h and held for 1 h. Subsequently the rate of cooling between each treatment temperature was 3 °C/h. Evaluated temperatures were 20, − 7, − 14 and − 21 °C and were achieved by manually adjusting the circulating bath temperature set point per the earlier performed calibration (Table <xref rid="Tab2" ref-type="table">2</xref>).<table-wrap id="Tab2" position="float" orientation="portrait"><label>Table 2</label><caption><p>Parts list for cooling device and supporting equipment</p></caption><table frame="hsides" rules="groups"><thead><tr><th align="left" colspan="1" rowspan="1">Description</th><th align="left" colspan="1" rowspan="1">Manufacturer/supplier</th><th align="left" colspan="1" rowspan="1">Part #</th></tr></thead><tbody><tr><td align="left" colspan="1" rowspan="1">Tubing</td><td align="left" colspan="1" rowspan="1">Fisher Scientific Saint-Gobain</td><td align="left" colspan="1" rowspan="1">14-169-1J</td></tr><tr><td align="left" colspan="1" rowspan="1">Inner insulation</td><td align="left" colspan="1" rowspan="1">Amazon (The Felt Store)</td><td align="left" colspan="1" rowspan="1">F-INVNEOADH-1</td></tr><tr><td align="left" colspan="1" rowspan="1">Outer insulation</td><td align="left" colspan="1" rowspan="1">Tundra</td><td align="left" colspan="1" rowspan="1">6XP068038</td></tr><tr><td align="left" colspan="1" rowspan="1">Neoprene sleeve</td><td align="left" colspan="1" rowspan="1">Seattle Fabrics</td><td align="left" colspan="1" rowspan="1">N3-2</td></tr><tr><td align="left" colspan="1" rowspan="1">Quick Connectors</td><td align="left" colspan="1" rowspan="1">McMaster-Carr</td><td align="left" colspan="1" rowspan="1">9198T16, 9198T18</td></tr><tr><td align="left" colspan="1" rowspan="1">Pump</td><td align="left" colspan="1" rowspan="1">Cole-Palmer Instruments Co</td><td align="left" colspan="1" rowspan="1">EW-77910-40</td></tr><tr><td align="left" colspan="1" rowspan="1">Circulating bath</td><td align="left" colspan="1" rowspan="1">Polyscience</td><td align="left" colspan="1" rowspan="1">AD07R-40</td></tr><tr><td align="left" colspan="1" rowspan="1">Coolant</td><td align="left" colspan="1" rowspan="1">Prestone</td><td align="left" colspan="1" rowspan="1">AF2000</td></tr><tr><td align="left" colspan="1" rowspan="1">Sample plugs</td><td align="left" colspan="1" rowspan="1">McMaster-Carr</td><td align="left" colspan="1" rowspan="1">9277K36 (e.g.)</td></tr><tr><td align="left" colspan="1" rowspan="1">Fluorinert (for sample chamber)</td><td align="left" colspan="1" rowspan="1">3 M</td><td align="left" colspan="1" rowspan="1">FC-3283</td></tr><tr><td align="left" colspan="1" rowspan="1">Vacuum grease</td><td align="left" colspan="1" rowspan="1">Variety Available</td><td align="left" colspan="1" rowspan="1">N/A</td></tr><tr><td align="left" colspan="1" rowspan="1">10–32 Nylon Bolt</td><td align="left" colspan="1" rowspan="1">McMaster-Carr</td><td align="left" colspan="1" rowspan="1">94320A430</td></tr><tr><td align="left" colspan="1" rowspan="1">Bolts 2</td><td align="left" colspan="1" rowspan="1">McMaster-Carr</td><td align="left" colspan="1" rowspan="1">95868A258</td></tr><tr><td align="left" colspan="1" rowspan="1">Small O-Ring</td><td align="left" colspan="1" rowspan="1">McMaster-Carr</td><td align="left" colspan="1" rowspan="1">9452K17</td></tr><tr><td align="left" colspan="1" rowspan="1">Large O-Ring</td><td align="left" colspan="1" rowspan="1">McMaster-Carr</td><td align="left" colspan="1" rowspan="1">1288N116</td></tr><tr><td align="left" colspan="1" rowspan="1">Device main body</td><td align="left" colspan="1" rowspan="1">Custom</td><td align="left" colspan="1" rowspan="1">N/A</td></tr><tr><td align="left" colspan="1" rowspan="1">Device cap</td><td align="left" colspan="1" rowspan="1">Custom</td><td align="left" colspan="1" rowspan="1">N/A</td></tr><tr><td align="left" colspan="1" rowspan="1">Sample holders</td><td align="left" colspan="1" rowspan="1">Custom</td><td align="left" colspan="1" rowspan="1">N/A</td></tr></tbody></table><table-wrap-foot><p>Cooling device parts and accessories, including manufacturer/supplier and part number. Custom pieces were designed and 3D printed; design files are available for download (in STL format) at <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="https://morgridge.org/designs">https://morgridge.org/designs</ext-link></p></table-wrap-foot></table-wrap></p></sec><sec id="Sec17"><title>Temperature calibration</title><p id="Par32">Since we lacked access to a MRI-compatible temperature probe able to measure freezing temperatures, the device sample holder temperature could not be actively monitored during the imaging runs. A calibration test was required to determine the sample temperature inside the cooling device relative to that reported by the circulating bath before imaging acquisition could occur. For this purpose, a central isolated conduit was included in the design of the device (Fig. <xref rid="Fig3" ref-type="fig">3</xref>) for the insertion of a non-MRI compatible copper-constantan (Type T) micro-thermocouple (36 AWG). This conduit allowed the junction of the thermocouple to reach the base of the sample chamber. The device was placed in the coil and bore of the MRI system to approximate the environment during data collection. Appropriate set points on the circulating bath were determined to reach the desired experimental temperatures.</p></sec><sec id="Sec18"><title>Data analysis</title><p id="Par33">Image files were viewed with Multi FDF Opener, a plugin of ImageJ, an open-source image analysis software package (NIH) [<xref ref-type="bibr" rid="CR20">20</xref>]. Images were normalized to the same window and level for comparing contrast between the different proton signal intensities for each of the evaluated temperatures. Image processing was performed using ImageJ. ROI were drawn on normalized images of individual buds based on features of <italic toggle="yes">V. macrocarpon</italic> anatomy. MGV were evaluated within the ROI and compared across all temperature treatments (Fig. <xref rid="Fig5" ref-type="fig">5</xref>g). The intensity of pixels decreased with freezing of the liquid water inside the bud tissues.</p></sec></sec></body><back><glossary><title>Abbreviations</title><def-list><def-item><term>MRI</term><def><p id="Par4">Magnetic resonance imaging</p></def></def-item><def-item><term>MGV</term><def><p id="Par5">Mean gray values</p></def></def-item><def-item><term>ROI</term><def><p id="Par6">Region of interest</p></def></def-item><def-item><term>CFT</term><def><p id="Par7">Controlled freezing test</p></def></def-item></def-list></glossary><fn-group><fn><p><bold>Publisher's Note</bold></p><p>Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p></fn><fn><p>Camilo Villouta and Benjamin L. Cox—co-first authors</p></fn></fn-group><ack><title>Acknowledgements</title><p>We thank Bill Wolfe from Wisconsin River Cranberry Co. for support of our research by giving access to his farm for <italic toggle="yes">V. macrocarpon</italic> samples. BLC and KWE acknowledge funding from the Morgridge Institute for Research.</p></ack><notes notes-type="author-contribution"><title>Authors' contributions</title><p>CV and BAW identified the need for a device to expose plant specimens to controlled freezing conditions while performing MRI. CV and BLC designed the device, with input from BAW, and drafted the original manuscript. BLC fabricated the device. CV performed prototype trials, and BR performed MRI scans and contributed to design features. CV, BLC, BAW, KWE, and AA provided critical reviews of the manuscript. BAW performed extensive editing. KWE and AA contributed guidance through the research process. All authors read and approved the final manuscript.</p><sec id="d32e1130"><title>Authors' information</title><p id="Par38">Camilo Villouta is a PhD candidate in the Department of Horticulture at the University of Wisconsin-Madison.</p><p id="Par39">Benjamin L. Cox is an Associate Lecturer of Biomedical Engineering in the Department of Biomedical Engineering at the University of Wisconsin-Madison and a Berbee-Walsh Postdoctoral Fellow at the Advanced Fabrication Laboratory in the Medical Engineering group at the Morgridge Institute for Research.</p><p id="Par40">Beth Rauch is a Senior Research Specialist, MRI technologist and Laboratory Manager at the Small Animal Imaging Center at the University of Wisconsin-Madison Carbone Cancer Center.</p><p id="Par41">Beth Ann A. Workmaster is a Researcher in the Fruit Crops Research Laboratory in the Department of Horticulture at the University of Wisconsin-Madison.</p><p id="Par42">Kevin W. Eliceiri is an Associate Professor of Medical Physics and Biomedical Engineering at the University of Wisconsin-Madison, and Director of the Fablab at the Morgridge Institute for Research.</p><p id="Par43">Amaya Atucha is an Assistant Professor in Fruit Crops in the Department of Horticulture at the University of Wisconsin-Madison.</p></sec></notes><notes notes-type="funding-information"><title>Funding</title><p>The authors would like to thank the Morgridge Institute for Research for their funding and support of this project. Funding for this work was also provided by the National Institute of Food and Agriculture, United States Department of Agriculture, through Hatch project 1009297, administered by the College of Agricultural and Life Sciences, University of Wisconsin-Madison.</p></notes><notes notes-type="data-availability"><title>Availability of data and materials</title><p>The designs files for the device presented here are available from the Morgridge Institute for Research repository at: <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="https://morgridge.org/designs">https://morgridge.org/designs</ext-link>.</p></notes><notes><title>Declarations</title><notes id="FPar1"><title>Ethics approval and consent to participate</title><p id="Par34">Not applicable.</p></notes><notes id="FPar2"><title>Consent for publication</title><p id="Par35">Not applicable.</p></notes><notes id="FPar3" notes-type="COI-statement"><title>Competing interests</title><p id="Par36">The authors declare they have no competing interests.</p></notes></notes><ref-list id="Bib1"><title>References</title><ref id="CR1"><label>1.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>George</surname><given-names>MF</given-names></name></person-group><article-title>Low temperature exotherm and woody plant distribution</article-title><source>HortScience</source><year>1974</year><volume>9</volume><issue>519</issue><fpage>22</fpage></element-citation></ref><ref id="CR2"><label>2.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>George</surname><given-names>MF</given-names></name><name name-style="western"><surname>Becwar</surname><given-names>MR</given-names></name><name name-style="western"><surname>Burke</surname><given-names>MJ</given-names></name></person-group><article-title>Freezing avoidance by deep undercooling of tissue water in winter-hardy plants</article-title><source>Cryobiology</source><year>1982</year><volume>19</volume><issue>6</issue><fpage>628</fpage><lpage>639</lpage><pub-id pub-id-type="doi">10.1016/0011-2240(82)90192-4</pub-id><pub-id pub-id-type="pmid">7151459</pub-id></element-citation></ref><ref id="CR3"><label>3.</label><mixed-citation publication-type="other">Levitt J. Responses of plants to environmental stress, vol 1: chilling, freezing, and high temperature stresses, 2nd edn. New York: Academic Press; 1980. pp. 497.</mixed-citation></ref><ref id="CR4"><label>4.</label><mixed-citation publication-type="other">Snyder RL, Melo-Abreu JP. Frost protection: fundamentals, practice and economics, vol 1. Frost protection, fundamentals, practice and economics. Roma: FAO. 2005. pp. 240</mixed-citation></ref><ref id="CR5"><label>5.</label><mixed-citation publication-type="other">Sakai A, Larcher W. Frost survival of plants: responses and adaptation to freezing stress, vol 62. Berlin: Springer Verlag. 1987. pp. 321.</mixed-citation></ref><ref id="CR6"><label>6.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ide</surname><given-names>H</given-names></name><name name-style="western"><surname>Price</surname><given-names>WS</given-names></name><name name-style="western"><surname>Arata</surname><given-names>Y</given-names></name><name name-style="western"><surname>Ishikawa</surname><given-names>M</given-names></name></person-group><article-title>Freezing behaviors in leaf buds of cold-hardy conifers visualized by NMR microscopy</article-title><source>Tree physiol</source><year>1998</year><volume>18</volume><issue>7</issue><fpage>451</fpage><lpage>458</lpage><pub-id pub-id-type="doi">10.1093/treephys/18.7.451</pub-id><pub-id pub-id-type="pmid">12651356</pub-id></element-citation></ref><ref id="CR7"><label>7.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ishikawa</surname><given-names>M</given-names></name><name name-style="western"><surname>Ide</surname><given-names>H</given-names></name><name name-style="western"><surname>Yamazaki</surname><given-names>H</given-names></name><name name-style="western"><surname>Murakawa</surname><given-names>H</given-names></name><name name-style="western"><surname>Kuchitsu</surname><given-names>K</given-names></name><name name-style="western"><surname>Price</surname><given-names>WS</given-names></name><etal/></person-group><article-title>Freezing behaviours in wintering Cornus florida flower bud tissues revisited using MRI</article-title><source>Plant Cell Environ</source><year>2016</year><volume>39</volume><issue>12</issue><fpage>2663</fpage><lpage>2675</lpage><pub-id pub-id-type="doi">10.1111/pce.12813</pub-id><pub-id pub-id-type="pmid">27497429</pub-id></element-citation></ref><ref id="CR8"><label>8.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Price</surname><given-names>WS</given-names></name><name name-style="western"><surname>Ide</surname><given-names>H</given-names></name><name name-style="western"><surname>Arata</surname><given-names>Y</given-names></name><name name-style="western"><surname>Ishikawa</surname><given-names>M</given-names></name></person-group><article-title>Visualisation of freezing behaviours in flower bud tissues of cold-hardy <italic toggle="yes">Rhododendron japonicum</italic> by nuclear magnetic resonance micro-imaging</article-title><source>Funct Plant Biol</source><year>1997</year><volume>24</volume><issue>5</issue><fpage>599</fpage><lpage>605</lpage><pub-id pub-id-type="doi">10.1071/PP97049</pub-id></element-citation></ref><ref id="CR9"><label>9.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ishikawa</surname><given-names>M</given-names></name><name name-style="western"><surname>Price</surname><given-names>WS</given-names></name><name name-style="western"><surname>Ide</surname><given-names>H</given-names></name><name name-style="western"><surname>Arata</surname><given-names>Y</given-names></name></person-group><article-title>Visualization of freezing behaviors in leaf and flower buds of full-moon maple by nuclear magnetic resonance microscopy</article-title><source>Plant physiol</source><year>1997</year><volume>115</volume><issue>4</issue><fpage>1515</fpage><lpage>1524</lpage><pub-id pub-id-type="doi">10.1104/pp.115.4.1515</pub-id><pub-id pub-id-type="pmid">12223878</pub-id><pub-id pub-id-type="pmcid">PMC158617</pub-id></element-citation></ref><ref id="CR10"><label>10.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Price</surname><given-names>WS</given-names></name><name name-style="western"><surname>Ide</surname><given-names>H</given-names></name><name name-style="western"><surname>Ishikawa</surname><given-names>M</given-names></name><name name-style="western"><surname>Arata</surname><given-names>Y</given-names></name></person-group><article-title>Intensity Changes in ^1H-NMR Micro-images of plant materials exposed to subfreezing temperatures</article-title><source>Bioimages</source><year>1997</year><volume>5</volume><issue>3</issue><fpage>91</fpage><lpage>99</lpage></element-citation></ref><ref id="CR11"><label>11.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Millard</surname><given-names>MM</given-names></name><name name-style="western"><surname>Veisz</surname><given-names>OB</given-names></name><name name-style="western"><surname>Krizek</surname><given-names>DT</given-names></name><name name-style="western"><surname>Line</surname><given-names>M</given-names></name></person-group><article-title>Magnetic resonance imaging (MRI) of water during cold acclimation and freezing in winter wheat</article-title><source>Plant Cell Environ</source><year>1995</year><volume>18</volume><issue>5</issue><fpage>535</fpage><lpage>544</lpage><pub-id pub-id-type="doi">10.1111/j.1365-3040.1995.tb00553.x</pub-id></element-citation></ref><ref id="CR12"><label>12.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Southon</surname><given-names>TE</given-names></name><name name-style="western"><surname>Mattsson</surname><given-names>A</given-names></name><name name-style="western"><surname>Jones</surname><given-names>RA</given-names></name></person-group><article-title>NMR imaging of roots: effects after root freezing of containerised conifer seedlings</article-title><source>Physiol Plant</source><year>1992</year><volume>86</volume><issue>2</issue><fpage>329</fpage><lpage>334</lpage><pub-id pub-id-type="doi">10.1034/j.1399-3054.1992.860221.x</pub-id></element-citation></ref><ref id="CR13"><label>13.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Borisjuk</surname><given-names>L</given-names></name><name name-style="western"><surname>Rolletschek</surname><given-names>H</given-names></name><name name-style="western"><surname>Neuberger</surname><given-names>T</given-names></name></person-group><article-title>Surveying the plant’s world by magnetic resonance imaging</article-title><source>Plant J</source><year>2012</year><volume>70</volume><issue>1</issue><fpage>129</fpage><lpage>146</lpage><pub-id pub-id-type="doi">10.1111/j.1365-313X.2012.04927.x</pub-id><pub-id pub-id-type="pmid">22449048</pub-id></element-citation></ref><ref id="CR14"><label>14.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kalcsits</surname><given-names>L</given-names></name><name name-style="western"><surname>Kendall</surname><given-names>E</given-names></name><name name-style="western"><surname>Silim</surname><given-names>S</given-names></name><name name-style="western"><surname>Tanino</surname><given-names>K</given-names></name></person-group><article-title>Magnetic resonance microimaging indicates water diffusion correlates with dormancy induction in cultured hybrid poplar (<italic toggle="yes">Populus</italic> spp.) buds</article-title><source>Tree physiol.</source><year>2009</year><volume>29</volume><issue>10</issue><fpage>1269</fpage><lpage>77</lpage><pub-id pub-id-type="doi">10.1093/treephys/tpp062</pub-id><pub-id pub-id-type="pmid">19696054</pub-id></element-citation></ref><ref id="CR15"><label>15.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Yooyongwech</surname><given-names>S</given-names></name><name name-style="western"><surname>Horigane</surname><given-names>AK</given-names></name><name name-style="western"><surname>Yoshida</surname><given-names>M</given-names></name><name name-style="western"><surname>Yamaguchi</surname><given-names>M</given-names></name><name name-style="western"><surname>Sekozawa</surname><given-names>Y</given-names></name><name name-style="western"><surname>Sugaya</surname><given-names>S</given-names></name><etal/></person-group><article-title>Changes in aquaporin gene expression and magnetic resonance imaging of water status in peach tree flower buds during dormancy</article-title><source>Physiol plant</source><year>2008</year><volume>134</volume><issue>3</issue><fpage>522</fpage><lpage>533</lpage><pub-id pub-id-type="doi">10.1111/j.1399-3054.2008.01143.x</pub-id><pub-id pub-id-type="pmid">18513373</pub-id></element-citation></ref><ref id="CR16"><label>16.</label><element-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Goldman</surname><given-names>M</given-names></name></person-group><source>Quantum description of high-resolution NMR in liquids</source><year>1988</year><publisher-loc>New York</publisher-loc><publisher-name>Oxford University Press</publisher-name></element-citation></ref><ref id="CR17"><label>17.</label><mixed-citation publication-type="other">Ritchie GA. Measuring cold hardiness. Techniques and Approaches in Forest Tree Ecophysiology (eds Lassoie JP, Hinckley TM). Boca Raton: CRC Press. 1991:557–82.</mixed-citation></ref><ref id="CR18"><label>18.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Neuner</surname><given-names>G</given-names></name><name name-style="western"><surname>Monitzer</surname><given-names>K</given-names></name><name name-style="western"><surname>Kaplenig</surname><given-names>D</given-names></name><name name-style="western"><surname>Ingruber</surname><given-names>J</given-names></name></person-group><article-title>Frost survival mechanism of vegetative buds in temperate trees: deep supercooling and extraorgan freezing versus ice tolerance</article-title><source>Front Plant Sci</source><year>2019</year><volume>10</volume><fpage>537</fpage><pub-id pub-id-type="doi">10.3389/fpls.2019.00537</pub-id><pub-id pub-id-type="pmid">31143193</pub-id><pub-id pub-id-type="pmcid">PMC6521125</pub-id></element-citation></ref><ref id="CR19"><label>19.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Villouta</surname><given-names>C</given-names></name><name name-style="western"><surname>Workmaster</surname><given-names>BAA</given-names></name><name name-style="western"><surname>Bolivar-Medina</surname><given-names>J</given-names></name><name name-style="western"><surname>Sinclair</surname><given-names>S</given-names></name><name name-style="western"><surname>Atucha</surname><given-names>A</given-names></name></person-group><article-title>Freezing stress survival mechanisms in <italic toggle="yes">Vaccinium macrocarpon</italic> Ait. terminal buds</article-title><source>Tree Physiol.</source><year>2020</year><volume>40</volume><issue>7</issue><fpage>841</fpage><lpage>55</lpage><pub-id pub-id-type="doi">10.1093/treephys/tpaa028</pub-id><pub-id pub-id-type="pmid">32163157</pub-id><pub-id pub-id-type="pmcid">PMC8493662</pub-id></element-citation></ref><ref id="CR20"><label>20.</label><element-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Schneider</surname><given-names>CA</given-names></name><name name-style="western"><surname>Rasband</surname><given-names>WS</given-names></name><name name-style="western"><surname>Eliceiri</surname><given-names>KW</given-names></name></person-group><article-title>NIH Image to ImageJ: 25 years of image analysis</article-title><source>Nat Methods</source><year>2012</year><volume>9</volume><issue>7</issue><fpage>671</fpage><pub-id pub-id-type="doi">10.1038/nmeth.2089</pub-id><pub-id pub-id-type="pmid">22930834</pub-id><pub-id pub-id-type="pmcid">PMC5554542</pub-id></element-citation></ref></ref-list></back></article>