EMD-8652
Cryo-EM structure of the human ether-a-go-go related K+ channel
EMD-8652
Single-particle4.0 Å
Deposition: 24/03/2017
Map released: 03/05/2017
Last modified: 13/03/2024
Concentration: 6
mg/mL
Details: A 1 mL peak fraction was collected and concentrated ~3x to obtain the final ~6 mg/mL sample.
Details: A 1 mL peak fraction was collected and concentrated ~3x to obtain the final ~6 mg/mL sample.
Buffer
pH: 7.4
Buffer components [7]:
Details: PH 7.4, adjusted with NaOH
Buffer components [7]:
Name | Formula | Concentration | ChEBI |
---|---|---|---|
HEPES | C8H18N2O4S | 20.0 mM | |
Potassium chloride | KCl | 300.0 mM | |
Dithiothreitol | C4H10O2S2 | 10.0 mM | |
N-Dodecyl beta-D-maltoside | C24H46O11 | 0.025 % | |
Cholesteryl hemisuccinate | C31H50O4 | 0.005 % | |
POPE:POPC:POPA 5:5:1 | - | 0.025 mg/mL | - |
Tris(2-carboxyethyl)phosphine | C9H15O6P | 0.5 mM |
Grid
Vitrification
Cryogen name: ETHANE
Chamber humidity: 98%
Chamber temperature: 298 K
Instrument: FEI VITROBOT MARK IV
Details: One blot: 3 second blot time, 0 blot force.
Chamber humidity: 98%
Chamber temperature: 298 K
Instrument: FEI VITROBOT MARK IV
Details: One blot: 3 second blot time, 0 blot force.
Microscope: FEI TITAN KRIOS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 300 kV
Nominal CS: 2.7 mm
Nominal defocus: 0.8 µm - 3.5 µm
Calibrated magnification: 38461.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Cooling holder cryogen: NITROGEN
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 300 kV
Nominal CS: 2.7 mm
Nominal defocus: 0.8 µm - 3.5 µm
Calibrated magnification: 38461.0
Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER
Cooling holder cryogen: NITROGEN
Image Recording
[1]
Detector model:
GATAN K2 SUMMIT (4k x 4k)
Detector mode: SUPER-RESOLUTION
Dimensions: 7420 pixel x 7676 pixel
Frames per image: 1-50
Number of grids: 1
Number of real images: 1505
Average exposure time: 15.0 s
Average electron dose per image: 85.0 e/Å2
Details: 50 0.3-second frames were collected for each movie at a dose rate of ~1.8 e-/A2/frame
Detector mode: SUPER-RESOLUTION
Dimensions: 7420 pixel x 7676 pixel
Frames per image: 1-50
Number of grids: 1
Number of real images: 1505
Average exposure time: 15.0 s
Average electron dose per image: 85.0 e/Å2
Details: 50 0.3-second frames were collected for each movie at a dose rate of ~1.8 e-/A2/frame
Final
reconstruction
Resolution: 4.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.143 CUT-OFF
Number of classed used: 4
Number of images used: 206
Algorithm: FOURIER SPACE
Resolution method: FSC 0.143 CUT-OFF
Number of classed used: 4
Number of images used: 206
Algorithm: FOURIER SPACE
⌯ Applied Symmetry
Point group:
C4
Software
[1]
Name | Version | Details |
---|---|---|
FREALIGN | 9.11 | - |
Startup model
[1]
⦨ Initial angle
assignment
⦩ Final angle assignment
Particle selection
[1]
Selected | Ref. model | Method | Software | Details |
---|---|---|---|---|
333000 | - | - | - | ~333k particles from autopick |
Final 3D classification
Number of classes:
8
Avg. number of members per classes: 41625.0
Avg. number of members per classes: 41625.0
Software
[1]
Name | Version | Details |
---|---|---|
RELION | 1.4 | - |
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Human ether-a-go-go related K+ channel
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Human ether-a-go-go related K+ channel
⬡ Geometry
X | Y | Z | |
---|---|---|---|
Dimensions | 256 | 256 | 256 |
Origin | 0 | 0 | 0 |
Spacing | 256 | 256 | 256 |
Voxel size | 0.56563 Å | 0.56563 Å | 0.46445 Å |
Contour list
Primary | Level | Source |
---|---|---|
True | 1.5 | AUTHOR |