EMD-2397
Cryo-EM reconstruction of enterovirus 71 in complex with a neutralizing antibody E18
EMD-2397
Single-particle10.0 Å
Deposition: 11/06/2013
Map released: 05/02/2014
Last modified: 19/02/2014
Concentration: 2
mg/mL
Buffer
pH: 8.0
Details: 10 mM Tris-HCl, pH 8.0, 0.5 M NaCl, and 1 mM EDTA
Details: 10 mM Tris-HCl, pH 8.0, 0.5 M NaCl, and 1 mM EDTA
Grid
Details: Quantifoin R1.2/1.3 Holey carbon 200Mesh
Vitrification
Cryogen name: ETHANE
Chamber humidity: 70%
Chamber temperature: 100 K
Instrument: HOMEMADE PLUNGER
Method: Blot for 2 second before plunging
Chamber humidity: 70%
Chamber temperature: 100 K
Instrument: HOMEMADE PLUNGER
Method: Blot for 2 second before plunging
Microscope: FEI/PHILIPS CM200FEG
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.0 mm
Nominal defocus: 0.00075 µm - 0.0045 µm
Nominal magnification: 50000.0
Calibrated magnification: 4950.0
Specimen holder model: OTHER
Alignment procedure: LEGACY (Astigmatism: Objective lens astigmatism was corrected at 100,000 times magnification, Electron beam tilt params: )
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.0 mm
Nominal defocus: 0.00075 µm - 0.0045 µm
Nominal magnification: 50000.0
Calibrated magnification: 4950.0
Specimen holder model: OTHER
Alignment procedure: LEGACY (Astigmatism: Objective lens astigmatism was corrected at 100,000 times magnification, Electron beam tilt params: )
Temperature
Minimum: 95
K
Average: 119 K
Maximum: 120 K
Average: 119 K
Maximum: 120 K
Image Recording
[1]
Detector category:
FILM
Detector model: KODAK SO-163 FILM
Scanner: NIKON SUPER COOLSCAN 9000
Number of real images: 112
Average electron dose per image: 18 e/Å2
Bits per pixel: 16.0
Detector model: KODAK SO-163 FILM
Scanner: NIKON SUPER COOLSCAN 9000
Number of real images: 112
Average electron dose per image: 18 e/Å2
Bits per pixel: 16.0
Details: Particles were boxed with e2boxer.py
Final
reconstruction
Resolution: 10.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 8335
Algorithm: OTHER
Details:
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 8335
Algorithm: OTHER
Details:
⌯ Applied Symmetry
Point group:
I
Software
[1]
Name | Version | Details |
---|---|---|
Eman, eman2 | - | - |
Final 2D classification
Number of classes:
122
CTF correction
Details:CTF determined for all particles from one film, phase flip
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Reconstruction of EV71 E18 Fab complex
Details: ::::EMDATABANK.org::::EMD-2397::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Reconstruction of EV71 E18 Fab complex
Details: ::::EMDATABANK.org::::EMD-2397::::
⬡ Geometry
X | Y | Z | |
---|---|---|---|
Dimensions | 200 | 200 | 200 |
Origin | -100 | -100 | -100 |
Spacing | 200 | 200 | 200 |
Voxel size | 2.48 Å | 2.48 Å | 2.48 Å |
Contour list
Primary | Level | Source |
---|---|---|
True | 1.0 | AUTHOR |